. EACH SETTING AND ADJUSTMENT
8
.1 IDLE CURRENT ADJUSTMENT
1. Idle Current Adjustment
Procedure
1
Turn on the power.
2
Perform aging for one minute.
3
Connect a digital voltmeter to the measurement point.
4
Turn the adjustment
V
R so that the voltage becomes
in 2.0 m
V
± 0.2 m
V
.
(Condition :
N
o signal and no load)
Adjustment
Points
V
R201
FL
V
R201
FR
V
R201
C
V
R201
SL
V
R201
SR
V
R201
SW
Measurement
Points
TP201
FL
3PI
N
: TEST POI
N
T(+)
TP201
FL
1PI
N
: TEST POI
N
T(-)
TP201
FR
3PI
N
: TEST POI
N
T(+)
TP201
FR
1PI
N
: TEST POI
N
T(-)
TP201
C
3PI
N
: TEST POI
N
T(+)
TP201
C
1PI
N
: TEST POI
N
T(-)
TP201
SL
3PI
N
: TEST POI
N
T(+)
TP201
SL
1PI
N
: TEST POI
N
T(-)
TP201
SR
3PI
N
: TEST POI
N
T(+)
TP201
SR
1PI
N
: TEST POI
N
T(-)
TP201
SW
3PI
N
: TEST POI
N
T(+)
TP201
SW
1PI
N
: TEST POI
N
T(-)
• Adjustment Point and Measurement Points
.... see fig1.
P.C.B SUB ASSY (AMP)
[fig 1.]
J
SIDE A
Idle current
V
R:
V
R201
FL
Idle current
V
R:
V
R201
SL
Idle current
V
R:
V
R201
SW
Idle current
V
R:
V
R201
C
Idle current
V
R:
V
R201
SR
Idle current
V
R:
V
R201
FR
TP201
FL
1PI
N
TEST POI
N
T(-)
TP201
SW
1PI
N
TEST POI
N
T(-)
TP201
C
1PI
N
TEST POI
N
T(-)
TP201
SL
1PI
N
TEST POI
N
T(-)
TP201
SR
1PI
N
TEST POI
N
T(-)
TP201
FL
3PI
N
TEST POI
N
T(+)
TP201
SL
3PI
N
TEST POI
N
T(+)
TP201
SW
3PI
N
TEST POI
N
T(+)
TP201
C
3PI
N
TEST POI
N
T(+)
TP201
SR
3PI
N
TEST POI
N
T(+)
TP201
FR
1PI
N
TEST POI
N
T(-)
TP201
FR
3PI
N
TEST POI
N
T(+)
Summary of Contents for SX-319V-K
Page 49: ...49 SX 319V K 5 6 7 8 5 6 7 8 A B C D E F ...
Page 55: ...55 SX 319V K 5 6 7 8 5 6 7 8 A B C D E F J CN401 M CP107 A FL FL FL SL SL SL SW C C C ...
Page 67: ...67 SX 319V K 5 6 7 8 5 6 7 8 A B C D E F B A SIDE B B P C B SUB ASSY P T ...
Page 73: ...73 SX 319V K 5 6 7 8 5 6 7 8 A B C D E F J 01 SIDE A SIDE B ...
Page 77: ...77 SX 319V K 5 6 7 8 5 6 7 8 A B C D E F L SIDE A ...
Page 79: ...79 SX 319V K 5 6 7 8 5 6 7 8 A B C D E F L SIDE B ...
Page 85: ...85 SX 319V K 5 6 7 8 5 6 7 8 A B C D E F P N SIDE B ...