AUTO

COOL

DRY

HEAT

FAN

AUTO

LOW

MED

HIGH

9

8

ON / OFF (Power) Button

Pressing this button once turns the power
to the system ON and OFF.

MODE (operation mode) Button

Pressing this button will switch its operating
modes in the following sequence of modes

Note: Cooling only versions of any system
will not respond to selection of HEAT mode. 

FAN SPEED (selector) Button

Pressing this button will switch the speed of
the indoor unit’s fan (air flow volume) in the
following sequence

Note: Fan speed can not be controlled by the
remote while running AUTO or DRY modes.

TURBO (Performance) Button

Pressing this button activates the high
performance function so that the system
can establish the the desired temperature
level within the shortest amount of time, in
both COOL and HEAT modes.
(if the air conditioner is not equipped with
this function it will not respond)

UP Temperature Button (      )

Pressing this button each time will increase
the set temperature in 1F increments up to
a maximum of 86F

DOWN Temperature Button (      )

Pressing this button each time will decrease
the set temperature in 1F increments down to
a minimum of 62F

Notes:

Temperature controls are not available
while running FAN mode.
Press and hold UP and DOWN buttons
simultaneously to change the display 
temperature between C and F degrees.

SILENCE (Quiet Mode) and 
FP (Low Heat) Dual Function Button

Pressing this button briefly will set the compressor
and the indoor fan motor to run at their lowest
allowed speed settings for extra quiet operation.
However, when running this mode, the cooling
and heating capacity may not be satisfactory
if the zone heating or cooling loads are higher
than this low capacity system operates at.

Pressing and holding this button for 2 seconds will
activate LOW-HEAT (or Vacation) Mode, useful
when the room will be unattended during winter
to prevent frost. This mode can only be activated
when system is in HEAT mode. LOW-HEAT mode
will set the temperature down to 46F and run low
heat cycle to save energy. Deactivate by pressing
POWER, FAN, FP, TEMP or MODE buttons.

TIMER ON Button

Pressing this button each time will advance the
setting time for automatically starting the
system by 30 min each press up to reaching
10.0 and 60 min each press thereafter.
 
  When the total set time elapses the
  system will start automatically.
  To cancel the ON set time, keep pressing the 
  TIMER ON button until display shows 0.0

MODE

MODE

FAN

TEMP

SLEEP

  

ON/OFF

SILENCE
      FP

TIMER

   ON

TIMER

   OFF

1

2

4

3

8

9

7

5
6

10

12

11

13

14

SWING   DIRECT

FOLLOW

      ME

LED

  SELF 

CLEAN

TURBO

Operational Buttons

4

5

6

SELF CLEAN Button

Pressing this button will activate a fan only
mode to dry the internal components before
long term stoppage. This mode can only be
activated under COOL or DRY modes and
lasts 16 minutes before system turns off.

SLEEP Button

Activates Sleep mode, according to the human
natural sleep cycle, by lowering or increasing
the set temperature in 2 steps. When activated,
this mode changes the set temperature by 2F
for each for each of the first and second hours
of the sleep cycle and turns the system off when
a total period of 8 hours elapses. Available in
COOL, HEAT and AUTO Modes. Press any of
MODE, FAN or POWER button to cancel.

Note on DUAL FUNCTION Buttons:

TURBO/SELF-CLEAN, SWING-DIRECT and
LED-FOLLOW-ME buttons are dual function
buttons. LEFT and RIGHT edges of these
buttons activate the different specific function
printed nearest to that edge.
SILENCE/FP button is also a dual function
button that works activates different functions
based on the length of time pressed, which is
further explained.

MODE

MODE

FAN

TEMP

SLEEP

  

ON/OFF

SILENCE
      FP

TIMER

   ON

TIMER

   OFF

1

2

4

3

8

9

7

5
6

10

12

11

13

14

SWING   DIRECT

FOLLOW

      ME

LED

  SELF 

CLEAN

TURBO

Operational Buttons

SLEEP Mode Details:

Human body temperature drops during sleep.
To match with this change in body temperature:

If the sleep mode is activated while running
COOL mode, the system will increase the set
temperature by 2F within 60 minutes and by
an additional 2F within the next 60 minutes.

If the sleep mode is activated while running
HEAT mode, the system will reduce the set
temperature by 2F within 60 minutes and by
an additional 2F within the next 60 minutes.

System turns off 8 hours after sleep mode is
activated. Use the Timer ON Function to start
the system automatically after sleep mode.

Summary of Contents for RG57A6

Page 1: ...C International Inc All rights reserved The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Read this manual carefully before operating your new air conditioning unit Make sure to save this manual for future reference MODE FAN TEMP SLEEP SWING DIRECT FOLLOW ME SELF CLEAN ON OFF SILENCE FP TIMER O...

Page 2: ...ns Auto Operation Cooling Heating Fan operation Dehumidifying Operation Timer Operation 23O F 140O F NOTE The layout of the functional buttons of this remote as shown here is for the standard model Actual model purchased may vary slightly from this version The signal output sent by this remote controller is processed entirely by the receiving air conditioning system In case any of the functions of...

Page 3: ...on Pressing this button each time will advance the setting time for automatically starting the system by 30 min each press up to reaching 10 0 and 60 min each press thereafter When the total set time elapses the system will start automatically To cancel the ON set time keep pressing the TIMER ON button until display shows 0 0 MODE MODE FAN TEMP SLEEP ON OFF SILENCE FP TIMER ON TIMER OFF 1 2 4 3 8 ...

Page 4: ...d below when it is ON Not applicable to this version MODE MODE FAN TEMP SLEEP ON OFF SILENCE FP TIMER ON TIMER OFF 1 2 4 3 8 9 7 5 6 10 12 11 13 14 SWING DIRECT FOLLOW ME LED SELF CLEAN TURBO Operational Buttons LED FOLLOW ME Dual Function Button FOLLOW ME PRESS AT RIGHT EDGE Press to activate internal temperature sensor in the remote controller instead of the one inside the air conditioner to mea...

Page 5: ... the difference between the actual ambient room temperature and the setting temperature on the remote controller 2 For the AUTO mode fan speed can not be selected Fan speed is automatically controlled in Auto Mode 3 If the Auto mode does not provide the desired comfort levels other suitable modes should be selected NOTE Dehumidifying operation MODE UP DOWN ON OFF 1 Press the button to select DRY m...

Page 6: ...cond delay before the remote controller transmits the signal to the air conditioner Then after approximately another 2 seconds the signal H will disappear and the set temperature will re appear on the LCD display window When you select the timer operation the remote controller automatically transmits the timer signal to the indoor unit for the specified time Therefore keep the remote controller in...

Page 7: ...r setting Example TIMER ON TIMER OFF Off Start Stop operation This feature is useful when you want to start the air conditioner before you wake up and stop it after you leave the house To start the air conditioner 2 hours after setting and stop it 5 hours after setting 1 Press the TIMER ON button 2 Press the TIMER ON button again to display 2 0H on the TIMER ON display 3 Press the TIMER OFF button...

Page 8: ...h the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following m...