PDA-4003
20
6. ADJUSTMENT
When Assy was exchanged or when E
2
PROM (IC8: 24LC16B)
was exchanged, CONTRAST and BRIGHTNESS adjustment are
necessary. This adjustment is done in the factory mode.
FACTORY MODE
How to Enter the Factory Mode
The factory mode enters when tact switch (S1) of DOWN
CONVERTER ASSY is pushed.
Adjustment Method
Adjustment Item
Input Signal
Measurement Point
Adjustment Method
CONTRAST adjustment
CN1-Pin2, CN2-Pin2
(DOWN CONVERTER
ASSY)
10 step signal
etc.
Adjust so that the signal amplitude of the input signal (CN1-Pin2) and
the output signal (CN2-Pin2) becomes same with the remote control
key.
BRIGHTNESS adjustment
When tact switch (S1) is pushed again, the factory mode is made
clear.
Selection of adjustment
Change of adjustment value
S1
Push
STANDBY
/ON
RGB1
RGB2
Y/C
MENU
MENU
SET
DOWN CONVERTER
VIDEO