50
M-AX10
Position
BRIDGE / DUAL
Attenuation (dB)
Serial Data
Binary
Code
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
00000
00001
00010
00011
00100
00101
00110
00111
01000
01001
01010
01011
01100
01101
01110
01111
10000
10001
10010
10011
10100
10101
10110
10111
11000
11001
11010
11011
11100
11101
11110
0
-2
-4
-6
-8
-10
-12
-14
-16
-18
-20
-22
-24
-26
-28
-30
-32
-34
-36
-38
-40
-42
-44
-46
-48
-50
-52
-54
-56
-58
Infinity
FFF
CB4
A17
804
65E
50E
404
331
289
203
199
145
102
CD
A3
81
66
51
40
33
28
20
19
14
10
C
A
8
6
5
0
-2.0021
-4.0026
-6.0015
-8.0013
-10.0064
-12.0052
-14.0006
-16.0002
-18.0089
-20.0106
-22.0074
-24.0127
-26.0100
-28.0013
-30.0333
-32.0731
-34.0754
-36.1215
-38.0937
-40.2039
-42.1421
-44.2863
-46.2245
-48.1627
-50.6615
-52.2451
-54.1833
-56.6821
-58.2657
#NUM!
0.0
-0.5
-1.0
-1.5
-2.0
-2.5
-3.0
-3.5
-4.0
-4.5
-5.0
-5.5
-6.0
-6.5
-7.0
-7.5
-8.0
-8.5
-9.0
-9.5
-10.0
-10.5
-11.0
-11.5
-12.0
-12.5
-13.0
-13.5
-14.0
-14.5
-15.0
FFF
F19
E41
D75
CB4
BFE
B53
AB0
A17
987
8FE
87D
804
791
725
6BE
65E
603
5AC
55B
50E
4C6
482
441
404
3CB
394
361
331
303
2D8
-0.5021
-1.0016
-1.5013
-2.0021
-2.5023
-3.0001
-3.5028
-4.0026
-4.5008
-5.0030
-5.5039
-6.0015
-6.5025
-7.0008
-7.5043
-8.0013
-8.5003
-9.0057
-9.5043
-10.0064
-10.5037
-11.0010
-11.5045
-12.0052
-12.5007
-13.0072
-13.5048
-14.0006
-14.5040
-15.0025
PROCESSOR
Attenuation (dB)
Serial Data
0.5
sec
1.0 sec
ON
OFF
ON
OFF
Indicator of the
operating mode
Indicator after
the switch is
operated
7. WARNING
7.1 Protection
When abnormal amplifier output is detected, the protection relay
and function muting are controlled to warn the user.
When P-DET (port 41) becomes "L," FMT (port 31) is set to "H"
and port 16 (SPRYH) is set to "L" immediately.
At the same time, ILL indicators flash in 1-second cycle.
(ILL1, ILL2) = (H, L)
↔
(L, L) (ILL1=port33(Pin33)
Flashing : Mode illumination light ILL2=port32(Pin32))
Mode indicator
Panel light
When the POWER OFF key is pressed, POWER OFF processing is
performed. (All other keys are disabled.)
Refer to 7.2 PROTECTION CIRCUIT about the circuit explanation.
7.2 Mode Switching
Mode switching is allowed only when the power is OFF.
If mode switching is performed with the power ON, relay is set to
OFF. When the previous status is restored, relay is returned to ON.
As a caution, the LED of the selected mode and the LED of the
operating mode flash with the timing shown below.
When the MODE switch is returned to its original setting, the LED
flashing as a caution stops, and normal status is resumed.
The MODE switch is read every loop.
When the MODE switch is operated when the ILL indicator is dark,
the indicator is forcibly turned on.
When the MODE switch setting matches the operating mode setting,
the ILL mode resumes its original status.
Relay is set to OFF in the MODE CAUTION status.