PDP-6010FD
133
5
6
7
8
5
6
7
8
C
D
F
A
B
E
Recovery flowchart (1-3)...Changing the VOL OFFSET setting voltage
[From the Main flowchart (1) ]
RST MASK 02 (Red)
Display RST MASK 03 (Green). / [MKS S53]
Set VOL OFFSET to the current setting value minus 48. / [VOF
***]
[To the Recovery flowchart (1-4)]
Display RST MASK 03 (Green). / [MKS S53]
Determine the current VOL OFFSET setting value as the final value.
Replacement of abnormal circuits or
re-replacement of the panel required
Replacement of abnormal circuits or
re-replacement of the panel required
No
Yes
Gradually decrease the VOL OFFSET value until disappear the
discharge (dead cell).
The VOL OFFSET value must be 107 or greater.
Current VOL OFFSET < 107?
No
Yes
Is there erroneous discharge (abnormal dead cell)?
(Check on the PANEL 1-ADJ menu.)
[To the Main flowchart (2)]
A