84
FH-P6600R,P6600
-
New Test Mode
S-CD plays the same way as before.
If an error such as off focus, spindle unlocking, unreadable sub-code, or sound skipping occurs after setup, its
cause and time occurred (in absolute time) are displayed.
During setup, operational status of the control software (internal RAM: CPOINT) is displayed.
These displays and functions are prepared for enhancing aging in the servicing and efficiency of trouble analysis.
(1) Shifting to the New Test Mode
1
Turn on the current test mode.
2
Select S-CD for the source through the specified procedure including use of the [SOURCE] key, and inserting the
disc. Then, press the [ 6 ] key while maintaining the regulator turned off.
3
After the above operations, the new test mode remains on irrespective of whether the S-CD is turned on or off.
You can reset the new test mode by turning on the reset start.
* With some products, the new test mode can be reset through the same operations as that employed for shifting to
the STBY mode (while maintaining the Acc turned off).
(2) Key Correspondence
Key
Test mode
New test mode
Power Off
Power On
In-play
Error Production
BAND
To power on
To power off
–
Time/Err.No. switching
(offset adjustment performed)
]
–
FWD-Kick
FF/TR+
–
[
–
REV-Kick
REV/TR-
–
1
–
T.Close (AGC performed)
Scan
–
/parameter display switching
2
RF AMP gain switching
Parameter display switching
Mode
–
/T.BAL adjustment/T.Open
3
To power on
F.Close/RF AGC/F.T.AGC
–
–
(offset adjustment not performed)
6
–
F.Mode switching
Auto/Manu T.No./Time switching
/T.Close (no AGC)/Jump switching
Note: Eject and CD on/off is performed in the same procedure as that for the normal mode.
(3) Cause of Error and Error Code
Code
Class
Contents
Description and cause
40
Electricity
Off focus detected.
FOK goes low.
→
Damages/stains on disc, vibrations or failure on servo.
41
Electricity
Spindle unlocked.
FOK = Low continued for 50 msec.
→
Damages/stains on disc, vibrations or failure on servo.
42
Electricity
Sub-code unreadable.
Sub-code was unreadable for 50 msec.
→
Damages/stains on disc, vibrations or failure on servo.
43
Electricity
Sound skipping detected.
Last address memory function was activated.
→
Damages/stains on disc, vibrations or failure on servo.
Note: Mechanical errors during aging are not displayed.
The error codes should be indicated in the same way as in the normal mode.
Summary of Contents for FH-P6600 ES
Page 5: ...5 FH P6600R P6600 8 9 10 11 13 1 2 4 3 12 17 18 14 5 16 15 7 6 2 2 PACKING FH P6600 ES ...
Page 7: ...FH P6600R P6600 7 2 3 EXTERIOR ...
Page 8: ...8 FH P6600R P6600 ...
Page 12: ...12 FH P6600R P6600 2 4 CD MECHANISM MODULE ...
Page 14: ...14 FH P6600R P6600 2 5 CASSETTE MECHANISM MODULE ...
Page 25: ...25 FH P6600R P6600 5 6 7 8 A B C D 5 6 7 8 B KV1410 23 ...
Page 27: ...27 FH P6600R P6600 5 6 7 8 A B C D 5 6 7 8 B KV1410 23 ...
Page 28: ...28 FH P6600R P6600 A CN857 A CN856 A 1 2 3 4 B C D 1 2 3 4 C 3 5 POWER SUPPLY UNIT ...
Page 29: ...29 FH P6600R P6600 ES RCA CORD C POWER SUPPLY UNIT 5 6 7 8 A B C D 5 6 7 8 C ...
Page 30: ...30 FH P6600R P6600 PTY D FUNC TAPE CN1102 CN1201 F E A 1 2 3 4 B C D 1 2 3 4 D 3 6 FLAP PCB ...
Page 39: ...39 FH P6600R P6600 ...
Page 44: ...44 FH P6600R P6600 E E E E E E IC Q FOPN FEJ FCLS A 1 2 3 4 B C D 1 2 3 4 A A AUDIO AMP UNIT ...
Page 45: ...45 FH P6600R P6600 E E E E E E E 5 6 7 8 A B C D 5 6 7 8 A SIDE B ...
Page 46: ...46 FH P6600R P6600 A 1 2 3 4 B C D 1 2 3 4 4 2 FM AM TUNER UNIT B SIDE A B FM AM TUNER UNIT A ...
Page 47: ...47 FH P6600R P6600 1 2 3 4 A B C D 1 2 3 4 B FM AM TUNER UNIT B SIDE B ...
Page 49: ...49 FH P6600R P6600 E E E RCA CORD CN857 A IC Q 5 6 7 8 A B C D 5 6 7 8 C SIDE A ...
Page 50: ...50 FH P6600R P6600 E E E E E IC Q A 1 2 3 4 B C D 1 2 3 4 C C POWER SUPPLY UNIT ...
Page 51: ...51 FH P6600R P6600 E E E E E E E E E 5 6 7 8 A B C D 5 6 7 8 C SIDE B ...
Page 57: ...CLAMP 57 FH P6600R P6600 1 2 3 4 A B C D 1 2 3 4 G SIDE B CONTROL UNIT S8TX G ...
Page 82: ...82 FH P6600R P6600 Grating waveform Ech Xch 20mV div AC Fch Ych 20mV div AC 45 0 75 60 30 90 ...