M-10X
19
6. ADJUSTMENT
6.1 IDLE CURRENT ADJUSTMENT
CAUTION : Heatsinks’ (Q323–Q326) DC level is equal to +B or –B.
Don’t touch them or you will be electricary chocked.
1. Connect the measuring instrument as Fig.6–1. (R415 or R416)
2. Set VR301 and VR302 to minimum.
3. Set the POWER switch to ON.
4. Adjust VR301 (VR302) so that the voltage between both sides of R415 (R416) becomes 16mV±1mV.
(Within 10 seconds from when the relay is turned ON)
5. Ages for 7 minutes.
6. Adjust VR301 (VR302) so that the voltage between both sides of R415 (R416) becomes 11mV±1mV.
Fig. 6–1 Adjustment Method
VR301
VR302
R413
R414
R415
R416
Heat Sink
CN204
AF ASSY
DC Voltmeter