DVR-A08XLA
11
5
6
7
8
5
6
7
8
C
D
F
A
B
E
3.1.3 INSPECTION (FAULT ANALYSIS PROGRAM) METHOD
Caution:
Please use in the Real MS-DOS mode. (The program does not work in the MS-DOS prompt (DOS window) of the
Windows.)
• Discs to be used
CD-ROM
:GGV1054
DVD-ROM (Single)
:GGV1035
DVD-ROM (Dual)
:GGV1036
DVD-RAM Recorded disc
:GGV1181
CD-R Blank disc
:GGV1126 (Mitsui) or GGV1216 (TAIYO-YUDEN)
CD-RW Blank disc
:GGV1088 (Multi Speed) or GGV1089 (High Speed) or GGV1215 (Ultra Speed)
DVD-R Blank disc
:GGV1139 (PIONEER or GGV1219 (TAIYO-YUDEN)
DVD-RW Blank disc
:GGV1170 (TDK) or GGV1218 (TDK)
DVD+R Blank disc
:GGV1217 (Mitsubishi-Chemical) or Richo
DVD+RW Blank disc
:GGV1220 (Mitsubishi-Chemical) or Richo
DVD+R DL Blank disc
:GGV1221 (Mitsubishi-Chemical) or Mitsubishi
• Inspection program disc
FA Program Disc: GGS1061
• Installation method
Copy the program file "R8a_fa.exe" .
• Execution method
1. Start the PC in the MS-DOS mode.
2. Move to the directory to which the program file has been copied.
Example: cd dvr108 [enter] (For "C:\dvr108")
3. Execute the program.
r8a_fa /e /sv [enter]
"OK" or "NG" is displayed here.
• Start-up screen
Operation
Key Operation
To move the window
Right
or
left
cursor keys
To select the measurement item
Up
or
down
cursor keys
To execute the measurement
Enter
key
To execute all items continuously
Space
key
To quit the program
Esc
key
Operation
Key Operation
To format
F
key
1. DVD-RW, 2. DVD+RW, 3. CD-RW
To select the drive unit
M
key
1. R7, 2. R6
R8 for FA (GGS1061)
r8a_fa.exe ver0.5
LDI C
heck