Request Sense
- 125 -
T
ABLE
2-31C
S
UPPORTED ADDITIONAL SENSE CODES AND ADDITIONAL SENSE CODE
QUALIFIERS
ASC
ASCQ
DESCRIPTION
00
00
no additional sense information
00
06
I/O process terminated
00
11
audio play operation in progress
00
12
audio play operation pause
00
13
audio play operation successfully completed
00
14
audio play operation stopped due to error
00
15
no current audio status to return
02
00
no seek complete
04
00
logical unit not ready, cause not reportable
04
01
logical unit is in process of becoming ready
04
02
logical unit not ready, initializing command required
04
03
logical unit not ready, manual intervention required
05
00
logical unit does not respond to selection
06
00
no reference position found
07
00
multiple peripheral devices selected
08
00
logical unit communication failure
08
01
logical unit communication time out
08
02
logical unit communication parity error
09
00
track following error
09
01
tracking servo error
09
02
focus servo failure
09
03
spindle servo failure
0A
00
error log overflow
11
00
unrecovered read error
11
05
L-EC uncorrectable error
11
06
CIRC unrecovered error
14
00
recorded entity not found
14
01
record not found
15
00
random positioning error
15
01
mechanical positioning error
15
02
positioning error detected by read of medium
17
00
recovered data with no error correction applied
17
01
recovered data with retries
17
02
recovered data with positive head offset
17
03
recovered data with negative head offset
17
04
recovered data with retries and/or CIRC applied
17
05
recovered data using previous sector ID
18
00
recovered data error correction applied
18
01
recovered data error correction and retries applied
18
02
recovered data - data auto - reallocated
18
03
recovered data with CIRC
18
04
recovered data with L-EC
18
05
recovered data - recommend reassignment
1A
00
parameter list length error
1B
00
synchronous data transfer error
20
00
invalid command operation code
CONTINUED
Summary of Contents for DR-706S
Page 2: ...CD ROM SCSI 2 Command Set R e f e r e n c e M a n u a l V e r s i o n 3 1 OB U0077C ...
Page 36: ...Inquiry 23 this page has been left intentionally blank ...
Page 106: ...Read CD ROM Capacity 93 this page has been left intentionally blank ...
Page 124: ...Read Sub Channel 111 this page has been left intentionally blank ...
Page 130: ...Read TOC 117 this page has been left intentionally blank ...
Page 140: ...Request Sense 127 this page has been left intentionally blank ...
Page 172: ...Read CD DA 159 this page has been left intentionally blank ...