6. ADJUSTMENT
6.1 OEL UNIT ADJUSTMENT
<When the OEL Unit has been replaced>
1. Use VR1970 to adjust the resistance between TP1 and TP3 to 11.4k
Ω
.
2. Use VR1971 to adjust the resistance between TP2 and TP3 to 5.8k
Ω
.
Digital Multi-Meter
KEYBOARD UNIT(SIDE B)
Adjustment point
TP1
TP3
TP2