49
DEH-M6006ZH,M6017ZH
1) Precautions
• This unit uses a single power supply (+5V) for the reg-
ulator. The signal reference potential, therefore, is
connected to REFO(approx. 2.5V) instead of GND.
If REFO and GND are connected to each other by mis-
take during adjustments, not only will it be impossi-
ble to measure the potential correctly, but the servo
will malfunction and a severe shock will be applied to
the pick-up. To avoid this, take special note of the fol-
lowing.
Do not connect the negative probe of the measuring
equipment to REFO and GND together. It is especially
important not to connect the channel 1 negative
probe of the oscilloscope to REFO with the channel 2
negative probe connected to GND.
Since the frame of the measuring instrument is usual-
ly at the same potential as the negative probe, change
the frame of the measuring instrument to floating sta-
tus.
If by accident REFO comes in contact with GND,
immediately switch the regulator or power OFF.
• Always make sure the regulator is OFF when connect-
ing and disconnecting the various filters and wiring
required for measurements.
• Before proceeding to further adjustments and mea-
surements after switching regulator ON, let the player
run for about one minute to allow the circuits to stabi-
lize.
• Since the protective systems in the unit's software are
rendered inoperative in test mode, be very careful to
avoid mechanical and /or electrical shocks to the sys-
tem when making adjustment.
• Disc detection during loading and eject operations is
performed by means of a photo transistor in this
unit.Consequently, if the inside of the unit is exposed
to a strong light source when the outer casing is
removed for repairs or adjustment, the following mal-
functions may occur.
*During PLAY, even if the eject button is
pressed,the disc will not be ejected and the unit
will remain in the PLAY mode.
*The unit will not load a disc.
When the unit malfunctions this way, either re-posi-
tion the light source, move the unit or cover the photo
transistor.
2) Test Mode
This mode is used for adjusting the CD mechanism
module of the device.
• Test mode starting procedure
Reset while pressing the
4
and
6
keys together.
• Test mode cancellation
Switch ACC, back-up OFF.
• After pressing the EJECT key, do not press any other
key until the disk is completely ejected.
• If the SEEK/SKIP+ or SEEK/SKIP- key is pressed while
focus search is in progress, immediately turn the
power off (otherwise the actuator may be damaged
due to adhesion of the lenses).
• Jump operation of TRs other than 100TR continues
after releasing the key. CRG move and 100TR jump
operations are brought into the “Tracking close” sta-
tus when the key is released.
6. ADJUSTMENT
6.1 CD ADJUSTMENT
Summary of Contents for DEH-M6006ZH
Page 4: ...4 DEH M6006ZH M6017ZH 2 2 EXTERIOR DEH M6006ZH A B ...
Page 6: ...6 DEH M6006ZH M6017ZH 2 3 EXTERIOR DEH M6017ZH A B ...
Page 8: ...8 DEH M6006ZH M6017ZH C D 2 4 CD MECHANISM MODULE ...
Page 29: ...29 DEH M6006ZH M6017ZH ...
Page 32: ...32 DEH M6006ZH M6017ZH 1 2 3 4 1 2 3 4 D C B A FRONT A A TUNER AMP UNIT ...
Page 33: ...33 DEH M6006ZH M6017ZH 5 6 7 8 5 6 7 8 D C B A A SIDE B ...
Page 35: ...35 DEH M6006ZH M6017ZH 1 2 3 4 1 2 3 4 D C B A B B KEYBOARD UNIT SIDE B A CN602 ...
Page 37: ...37 DEH M6006ZH M6017ZH 1 2 3 4 1 2 3 4 D C B A B B KEYBOARD UNIT SIDE B A CN602 ...
Page 39: ...39 DEH M6006ZH M6017ZH D C B A 1 2 3 4 1 2 3 4 SIDE B C CLAMP CONTROL UNIT C ...
Page 60: ...60 DEH M6006ZH M6017ZH 7 1 3 CONNECTOR FUNCTION DESCRIPTION ANTENNA JACK ...