54
DEH-240F,2400F,24F
7.3 OPERATIONAL FLOW CHART
VDD=5V
Pin 68
Power ON
BSENS=L
ASENS=L
DSENS=L
bsens
Pin 63
asens
Pin 64
dsens
Pin 65
ADPW
←
H
Pin 66
swvdd
←
L
Pin 41
Source keys
operative
Completes power-on operation.(After that, proceed to each source operation.)
SYSPW
←
H
Pin 42
Starts communication with Grille microcomputer.
Source ON
300ms
300ms
In case of the above signal, the communication
with Grille microcomputer may fail.
If the time interval is not 300msec, the oscillator
may be defective.
CSENS
Pin 80
2V<CSENS<4V
-
CSENS 2V, 3V CSENS
Source returns to the original one(before you open).
CD loading functions are available.
Keys except for EJECT key are not available.