26
DDJ-WEGO-K
1
2
3
4
A
B
C
D
E
F
1
2
3
4
3
W
hen targeted kno
b
is decided, p
u
sh the Rotary selector and start o
b
servation of A/D conversion val
u
e.
Get the A / D conversion val
u
e immediately after the start. It
w
ill
b
e reference val
u
e.
* A / D conversion val
u
e to
b
e monitored is Ra
w
data.
4
Start monitoring and later to monitor the A / D conversion val
u
e, do the follo
w
ing actions depending on its val
u
e.
5
By p
u
shing the Rotary selector
w
hile monitoring the conversion val
u
e A / D, it is possi
b
le to reset the state of the
fl
u
ct
u
ations of the past.
1. T
u
rn the left deck EQ (HI) control to the position yo
u
w
ant
to
meas
u
re.
6. More time has elapsed, Channel level indicator is lit as
follo
w
s:
b
ecome the val
u
e 764 of the A / D.
7. More time has elapsed, Channel level indicator is lit as
follo
w
s:
b
ecome the val
u
e 75
8
of the A / D.
10. Off all the Channel level indicator
w
hen yo
u
p
u
sh the
Rotary selector, and this val
u
e
w
ill
b
e ne
w
reference
val
u
e.
8
. More time has elapsed, To maintain the a
b
ove display
759 even tho
u
gh the val
u
e of the A / D.
9. More time has elapsed, Channel level indicator is lit as
follo
w
s:
b
ecome the val
u
e 757 of the A / D.
2. T
u
rned right 3 clicks Rotary selector.
→
HOT CUE 2 of the left deck is lit.
3. Start A/D conversion val
u
e monitoring to p
u
sh Rotary
selector.
If A/D val
u
e of p
u
sh the Rotary selector is 760, To monitor
the
amo
u
nt of change in the val
u
e of A / D as a reference
val
u
e 760.
4. After a
w
hile, Channel level indicator is lit as follo
w
s:
b
ecome the val
u
e 763 of the A / D.
5. More time has elapsed, To maintain the a
b
ove display
762 even tho
u
gh the val
u
e of the A / D.
Ex.)
Left Deck
1
+1 from the reference val
u
e A / D conversion val
u
e
The 1st to
b
e lit from the
b
ottom of the right Channel Level Indicator
2
+2 from the reference val
u
e A / D conversion val
u
e
The 1st - 2nd to
b
e lit from the
b
ottom of the right Channel Level Indicator
3
+3 from the reference val
u
e A / D conversion val
u
e
The 1st - 3rd to
b
e lit from the
b
ottom of the right Channel Level Indicator
4
+4 from the reference val
u
e A / D conversion val
u
e
* Display at the same time
b
oth fall / rise direction from the reference val
u
e of the conversion val
u
e A/D
* Keep the lighting position at the time of maxim
u
m fl
u
ct
u
ation of
each of the positive & negative direction
The 1st - 4th to
b
e lit from the
b
ottom of the right Channel Level Indicator
5
over +5 From the reference val
u
e A / D conversion val
u
e The 1st - 5th to
b
e lit from the
b
ottom of the right Channel Level Indicator
6
-1 From the reference val
u
e A / D conversion val
u
e
The 5th is lit from the
b
ottom of the left Channel Level Indicator
7
-2 From the reference val
u
e A / D conversion val
u
e
The 4th - 5th is lit from the
b
ottom of the left Channel Level Indicator
8
-3 From the reference val
u
e A / D conversion val
u
e
The 3rd - 5th is lit from the
b
ottom of the left Channel Level Indicator
9
-4 From the reference val
u
e A / D conversion val
u
e
The 2nd - 5th is lit from the
b
ottom of the left Channel Level Indicator
10
less than -5 From the reference val
u
e A / D conversion val
u
e
The 1st - 5th is lit from the
b
ottom of the left Channel Level Indicator
1
2
3
4
5
6
7
8
9
10