43
DDJ-ERGO-V
5
6
7
8
5
6
7
8
A
B
C
D
E
F
8
. EACH SETTING AND ADJUSTMENT
8
.1 NECESSARY ITEMS TO BE NOTED
8
.2 HOW TO PROGRAM COPY FOR USB CONTROLLER
Perform the corresponding task(s) in the described order after any of the following parts is replaced:
After repairing, be sure to check the version of the firmware, and if it is not the latest one,
update to the latest version
.
In addition, be sure to reset the unit to
the default settings
, using Factory Reset mode, before
returning the repaired product to the user.
• MAI
N
UCOM (CDJ1 Assy: IC1002)
• Confirmation of the version of the firmware
• Updating to the latest version of the firmware
• EEPROM (IFP
W
Assy: IC104)
• Copying the program for the USB controller
• Updating to the latest version of the firmware
• Copying the program for the USB controller
• Component parts of the JOG dial section
• JOG dial rotation load adjustment
1. Check that the controller is OFF.
2.
W
hile holding the LOOP OUT 1 and
V
I
N
YL 1 buttons pressed, set the Power switch of the unit to O
N
.
N
ote:
N
E
V
ER release the above-mentioned two buttons while the FU
N
CTIO
N
LED is lit.
3. After making sure that the FU
N
CTIO
N
LED is unlit, set the Power switch of the unit to OFF.
LOOP OUT 1 button : S1227
V
I
N
YL 1 button
: S120
8
FU
N
CTIO
N
LED
: D1203
N
ote: If copying fails, the FU
N
CTIO
N
LED will flash at intervals of 0.25 sec.