CT-S670D
38
Error
Service No.
Occurrence Condition
Cause
Location
BLE
B1
The takeup-side reel base has stopped during
The tape end has been reached.
BLE operation.
The reel motor has stopped.
The capstan motor has stopped.
B2
No signal has been recorded on the tape during
The used tape differs widely from the caracteristics
BLE operation.
of the standard tape.
The internal oscillator is not oscillating.
Defect of compensation circuit parts, defective contact, etc.
Loading
L1
During OPEN/CLOSE operation, the loading
The tape has not been set correctly.
mechanism has not reached the target position.
Entry of foreign objects etc.
Mechanism
M1
The takeup-side reel base has stopped and the
The reel motor has stopped.
supply-side reel base is operating.
The tape has become wound to the capstan because
of static electricity.
Digital
D1
The digital input 1 does not receive a digital input
signal of fs = 44.1 kHz.
D2
The digital input 2 does not receive a digital input
signal of fs = 44.1 kHz.
(8) NTF Error Code Check Mode
Entering the check mode
In mechanism operation check mode, press the METER RANGE key to set the level (MS) display to “ 7* ”.
When the METER RANGE key is pressed again, the error code for the previous error is displayed (max. 3 errors).
Exiting the check mode
When the STOP key is pressed, mechanism operation check mode is set.
When repair has been completed, reset the recorded reeor. (Press the MODE key and RESET key together.)
Check mode display
NTF Error display
Resetting the error code
To reset, press the MODE key and MUTE key together.
Service Number
Test Mode No.
Error Counter
Counter