39
CDX-FM1277,FM1279
-
CD Test mode
This mode is used for adjusting the CD mechanism
module of the device.
• Test mode starting procedure
Reset while pressing the 4 and 6 keys together.
• Test mode cancellation
Switch ACC, back-up OFF.
• If the 8 or 9 key is pressed while focus search is in
progress, immediately turn the power off (otherwise
the actuator may be damaged due to the lens stuck).
• Jump operation of TRs other than 100TR continues
after releasing the key. CRG move and 100TR jump
operations are brought into the “Tracking close” sta-
tus when the key is released.
• Powering Off/On resets the jump mode to “Single TR
(91)”, the RF AMP gain setting to 0 dB, and the auto-
matic adjustment value to the initial value.
• During exchanging discs, do not press the keys for
the discs to be exchanged.
• The following head units are exceptional so that their
entering ways to the test mode are different from oth-
ers.
Test mode starting procedure
Reset while pressing the 3 and 5 keys together.
KEH-P5010R/X1M/EW
KEH-4011/X1M/EE
KEH-P5011/X1M/EE
KEH-4010R/X1M/EW
KEH-P4010RB/X1M/EW
KEH-P4013R/X1M/EW
KEH-5015/X1M/ES
KEH-P4010/X1M/UC
KEH-P4015/X1M/ES
Summary of Contents for CDX-FM1277
Page 6: ...6 CDX FM1277 FM1279 2 2 EXTERIOR ...
Page 8: ...8 CDX FM1277 FM1279 2 3 CD MECHANISM MODULE ...
Page 16: ...16 CDX FM1277 FM1279 1 2 3 4 1 2 3 4 D C B A SYSTEM CONTROLLER A 1 2 A2 2 ...
Page 17: ...17 CDX FM1277 1279 5 6 7 8 5 6 7 8 D C B A SRAM IP BUS DRIVER B CN201 A2 2 ...
Page 21: ...21 CDX FM1277 FM1279 ...
Page 27: ...27 CDX FM1277 FM1279 1 2 3 4 1 2 3 4 D C B A E E IC Q RESET EJECT MAG SIDE B CD CORE UNIT A A ...
Page 29: ...29 CDX FM1277 FM1279 1 2 3 4 1 2 3 4 D C B A B E E IC Q EXTENSION UNIT B SIDE B ...
Page 33: ...E E E IC Q 33 CDX FM1277 FM1279 1 2 3 4 1 2 3 4 D C B A G SIDE B DISPLAY ASSY G ...
Page 57: ...57 CDX FM1277 FM1279 7 2 2 DISPLAY CAW1514 COMMON SEGMENT ...