40
CDX-FM1259,FM1257
4. Press key 9 to set ELV/TRAY mode to TRAY.
5. Press key FF to release the clamp and return the tray to the magazine.
6. Press key 9 to enter Elevation Move mode.
7. Use key FF/REV to operate elevation and set if to the graduation of the sixth step
(Fig. 1).
8. Make the adjustment.
Use VR802 to adjust the difference in potential between EREF and EPVO to 0 ±10
mV.
9. When adjustment is completed, press key BAND to exit Mechanism Test mode.
10. Confirm operation of the mechanism.
Place the mechanism horizontally (CD core unit below). Take care not to short-cir-
cuit the PCB.
11. Confirm the height of the stage. Use the Disc± key to select Disc No.6.
Check if the stopper bend of the clamp lever is engaged in the groove of the frame
stopper (Fig. 2-4).
• Note :
The stopper bend will be pressed downward into the groove for final clamping. Confirm the engagement position
of the stopper bend.
• If the stopper bend is engaged in the center and pressed downward, adjustment is completed. Go to step 15.
• If the stopper bend is dislocated, check the amount of dislocation by following steps 12 to 14.
TRACK
FUNCTION
72
00' 02"
TRACK
FUNCTION
72
00' 02"
TRACK
FUNCTION
'
"
TRACK
FUNCTION
04
00' 00"
Examples of display
TRACK
FUNCTION
72
01' 02"
Release the clamp
Summary of Contents for CDX-FM1257
Page 6: ...6 CDX FM1259 FM1257 2 2 EXTERIOR ...
Page 8: ...8 CDX FM1259 FM1257 2 3 CD MECHANISM MODULE ...
Page 19: ...19 CDX FM1259 FM1257 ...
Page 27: ...27 CDX FM1259 FM1257 D C B A B EXTENSION UNIT B SIDE B 1 2 3 4 1 2 3 4 ...
Page 49: ...49 CDX FM1259 FM1257 7 1 2 DISPLAY CAW1514 COMMON SEGMENT ...
Page 58: ...58 CDX FM1259 FM1257 7 3 BLOCK DIAGRAM A C D E B ...
Page 59: ...59 CDX FM1259 FM1257 F G ...