BDP-94HD
31
5
7
8
5
6
7
8
C
D
F
A
B
E
7. DISASSEMBLY
1
Remove the Bonnet Case by removing the eight screws.
2
Press the STANDBY/ON button to turn on the power.
3
Press the OPEN/CLOSE button to open the Tray.
4
Remove the Tray Panel.
6
7
Press the STANDBY/ON button to turn off the power.
Pull out the Power cord.
1
Insert GGF1529 into bore as shown in the following figure.
If the Tray pops out a little, fully pull it out by hand.
Bonnet Case and Tray Panel
1
4
Tray Panel
Tray
How to open the Tray when the power cannot be on
Diagnosis of PCB's
Note 1:
Do NOT look directly into the pickup lens. The laser beam may cause eye injury.
Note 2:
Even if the unit shown in the photos and illustrations in this manual may differ from your product, the procedures
described here are common.
Note 3:
For the performing the diagnosis shown below, the following jigs for service are required.
• GGF1529 : Emerqency tray ejection rod.
• GGF1533 : BB Extension board
• GGD1437 : BB Extension cable
2
Tray
Tray open
1
3
3
6
3
Press the OPEN/CLOSE button to close the Tray.
5
www. xiaoyu163. com