42
BDP-09FD
1
2
3
4
A
B
C
D
E
F
1
2
3
4
[6] ERROR RATE MEASUREMENT 1 AND OK/NG JUDGMENT
Use the error rate measurement for failure judgment of the DRI
V
E Assy or a disc.
If a measured error rate is outside the range of the standard values, check if the DRI
V
E Assy is in failure, by comparing the
product or the DRI
V
E Assy with a product or DRI
V
E Assy in normal state.
To measure the error rate for a certain duration, press the ESC then SIDE-B keys only during playback. The result of judgment
(OK/
N
G) will be displayed on the FL display and as an OSD.
To exit Error Rate Measurement mode, press the ESC key while the error rate is being measured.
After exiting Error Rate Measurement mode, if the ESC then SIDE-B keys are pressed again to reenter Error Rate Measure-
ment mode, measurement of the error rate will start from the beginning.
The error rate is measured for up to 5 sessions, and the displayed result is updated after measurement for each session is
performed.
At the end of 5 sessions, the average error rate for the entire measurement range will be displayed. If measurement sessions
are interrupted before 5 sessions, the average error rate up to the point of interruption will be calculated and displayed.
A result will be judged as
N
G if the measured error rate exceeded the reference value. See "OK/
N
G judgment" below.
(Only when the average error rate is judged as
N
G, the tray will be opened.)
Display Formats on the FL display and as an OSD
OK/NG jud
g
ment
FL
Operation
Disc type
Reference value
Indication
Only during playback, if keys are pressed, calculation of error
rate is started, and the results are displayed on the FL display
and as an OSD. The symbol (-) (which indicates that measure-
ment is not finished) flashes.
(At lights out)
ER x . x E - x
(At lighting)
ERR RATE : x.xE-x (At lights out)
ERR RATE : x.xE-
∗
OK
(
N
G: OSD whole screen display
with red)
ERR RATE : x.xE-x- ERROR
D
V
D
BD
CD
1.0x10
-3
1.0x10
-3
N
o error rate measurement
OK/
N
G
OK/
N
G
ERR RATE : x.xE-x- (At lighting)
The result of measurement is displayed.
If error rate measurement is completed before playback
finishes, the average error rate, the symbol (*) (which indicates
that the measurement is completed) and the judgment result
(OK/
N
G) will be displayed on the FL and as an OSD.
(When
N
G is displayed, if the tray is opened, the indications on
the FL display and screen will be retained.)
If error rate measurement is not completed before playback
finishes, the average error rate, the symbol (-) (which indicates
that measurement is not finished) and the judgment result
(ERROR) that indicates that the error rate measurement has
not been completed will be displayed on the FL display and as
an OSD.
OSD
Display format
* The layout for OSD depends on the mounting.
* "x.xE-X" in the above table indicates an error rate. E.g.: 3.5E-5 = 3.5X10
-5
ER x . x E -
-
x
ER x . x E - x
∗
ER x . x E -
-
x
[5] SELF-DIAGNOSIS RESULT DISPLAY
Each time the power is turned O
N
a self-diagnosis is performed during startup, and its result can be used for a failure
analysis.
Press the [ESC], [DISP], then [4] keys, in that order, to display the result of the self-diagnosis performed during startup
through communication. Any abnormality that is generated after startup will not be displayed.
1
SKY Chip Info:
V
ersion and revision
N
os. of the SKY Chip
2
HDMI Transmitter: Result of checking communications with the SII9134CTU
3
SUBCO
N
: Result of checking communications with the LC
8
7F5932A
4
PLL Synthesizer: Result of checking communications with the CDCE906
5
DRI
V
E: Result of checking communications with the BD drive
1
2
3
4
5
• Specifications of indications for the results of self-dia
g
nosis