56
TS5, BCT-1510, BCT-1520,
BCT-1530
•
Pin Function (3/3)
DTE USER
NAME
PIN
TYPE
DESCRIPTION
EXCLK
22
I
EXTERNAL CLOCK: This signal is used in synchronous
transmission when the external timing option has been
selected. In the external timing mode the rising edge of
EXCLK is used to strobe synchronous DPSK transmit data
applied to on the TXD pin. Also used for serial control
interface.
RXCLK
26
O
RECEIVE CLOCK: The falling edge of this clock output is
coincident with the transitions in the serial received data
output. The rising edge of RXCLK can be used to latch the
valid output data. RXCLK will be valid as long as a carrier is
present.
RXD
25
O
RECEIVED DATA OUTPUT: Serial receive data is available
on this pin. The data is always valid on the rising edge of
RXCLK when in synchronous mode. RXD will output constant
marks if no carrier is detected.
TXCLK
21
O
TRANSMIT CLOCK: This signal is used in synchronous
transmission to latch serial input data on the TXD pin. Data
must be provided so that valid data is available on the rising
edge of the TXCLK. The transmit clock is derived from
different sources depending upon the synchronization mode
selection. In internal mode the clock is generated internally. In
external mode TXCLK is phase locked to the EXCLK pin. In
slave mode TXCLK is phase locked to the RXCLK pin.
TXCLK is always active.
TXD
24
I
TRANSMIT DATA INPUT: Serial data for transmission is
applied on this pin. In synchronous modes, the data must be
valid on the rising edge of the TXCLK clock. In asynchronous
modes (1200/600 bps or 300/1200 baud) no clocking is
necessary. DPSK data must be 1200/600 bps +1%, -2.5% or
+2.3%, -2.5 % in extended over speed mode.
.
ANALOG INTERFACE AND OSCILLATOR
NAME
PIN
TYPE
DESCRIPTION
RXA
32
I
Received modulated analog signal input from the telephone
line interface.
TXA1 / TXA 2
18 / 17
O
(differential) Transmit Analog. These pins provide the analog
output signals to be transmitted to the telephone line. The
drivers will differentially drive the impedance of the line
transformer and the line matching resistor. An external hybrid
can also be built using TXA1 as a single ended transmit
signal.
XTL1 / XTL2
3 / 4
I
These pins are for the internal crystal oscillator requiring a
11.0592 MHz parallel mode crystal. Load capacitors should
be connected from XTL1 and XTL2 to ground. XTL2 can also
be driven from an external clock.
OH
27
O
OFF-HOOK RELAY DRIVER: This signal is an open drain
output capable of sinking 40 mA and is used for controlling a
relay. The output is the complement of the OH register bit in
the ID Register.
Summary of Contents for BCT-1510
Page 3: ...3 TS5 BCT 1510 BCT 1520 BCT 1530 ...
Page 15: ...TS5 BCT 1510 BCT 1520 BCT 1530 15 A B C D 5 6 7 8 5 6 7 8 3 7 A SDRAM 16M A 7 7 A 2 7 A 2 7 ...
Page 19: ...TS5 BCT 1510 BCT 1520 BCT 1530 19 A B C D 1 2 3 4 1 2 3 4 ...
Page 21: ...TS5 BCT 1510 BCT 1520 BCT 1530 21 A B C D 5 6 7 8 5 6 7 8 6 7 A A 7 7 Modem IC Modular Jack ...
Page 32: ...TS5 BCT 1510 BCT 1520 BCT 1530 32 A B C D 1 2 3 4 1 2 3 4 A MAIN ASSY A ...
Page 33: ...TS5 BCT 1510 BCT 1520 BCT 1530 33 A B C D 5 6 7 8 5 6 7 8 A BNP1354 D SIDE B ...