AVH-X1500DVD/XNUC
97
5
6
7
8
5
6
7
8
C
D
F
A
B
E
Procedure of Power Adjustment
Flow
1. DVD Power adjustment in the state where F is ON
2. DVD Power adjustment in the state where the setup is completed
3. CD Power adjustment in the state where F is ON
4. CD Power adjustment in the state where the setup is completed
Procedure of Adjustment
1. Set the mecha to clockwise.
2. Turn on power.
3. Test Mode In
4. Insert DVD TDV-582 (or TDV-520).
5. Set the mecha to counterclockwise.
6. Adjustment of the initial position of VR for Power adjustment
7. Set DISC TYPE to DVD single layer.
8. Power on.
9. LD-ON.
10. Execute until Focus close state is reached.
If the waveform is similar to RF waveform after F-ON and before T-ON (waveform measured by analog oscilloscope), Focus Close is reached.
Go to STEP 9.
If the RF waveform does not appear, Focus Close is not reached.
Return to STEP 7 and change the angle of initial position of DVD VR (VR 1102). If Focus Close is not reached after the 3rd VR adjustment,
replace the whole CRG mecha (including PU unit) and start again from STEP 1.
11. Conduct Power adjustment. (Conduct the adjustment in the state of Focus Close.)
12. Execute until Tracking Close is reached.
13. Conduct Power adjustment. (Conduct the adjustment in the state of Tracking Close.)
14. Check the ERR rate after Power adjustment.
15. Power off.
16. Return the state of mecha to clockwise.
17. Set up again (state of mecha to clockwise / setting of DVD single layer) and conduct the final check of RF level and ERR rate.
(Check in the state of Tracking Close)
18. Eject.
Refer to FE test mode function flow.
1st
2nd
3rd
CD
(VR1101)
DVD (VR1102)
-30°
-45°
-90°
DVD
DVD
DVD
DVD
DVD
-30°
2.0E – 4 and under
820 mV to 917 mV
200 mV to 1200 mV
848 mV to 892 mV
2.0E – 4 and under
0°
0°
DVD VR (VR1102)
Adjustment of the initial
position
1st - -30°
2nd - -45°
3rd - -90°
Adjust the angle at the D cut position to the initial position
(initial position shown in Fig.1).
Refer to FE test mode function flow.
Refer to FE test mode function flow.
Refer to FE test mode function flow.
STEP No.
CD VR (VR1101)
Adjustment of the initial position
-30° - 1st, 2nd, 3rd is the same, too
Fig.1
Summary of Contents for AVH-X1500DVD/XNEW5
Page 12: ...AVH X1500DVD XNUC 12 1 2 3 4 1 2 3 4 C D F A B E UW5 Type Backup current 5 mA or less ...
Page 13: ...AVH X1500DVD XNUC 13 5 6 7 8 5 6 7 8 C D F A B E UW5 Type ...
Page 25: ...AVH X1500DVD XNUC 25 5 6 7 8 5 6 7 8 C D F A B E ...
Page 103: ...AVH X1500DVD XNUC 103 5 6 7 8 5 6 7 8 C D F A B E ...
Page 111: ...AVH X1500DVD XNUC 111 5 6 7 8 5 6 7 8 C D F A B E ...