Pintech PT-710 Instruction Manual Download Page 2

instruction manual for further ratings information before making connections to the product.

Replace Batteries Properly.

Replace batteries only with the proper type and rating specified.

Do Not Operate Without Covers.

Do not operate this product without the covers or panels.

Avoid Exposed Circuitry.

Do not touch exposed connections and components when power is present.

Do Not Operate With Suspected Failures.

If you suspect there is damage to this product, have it inspected by qualified service personnel.

Do Not Operate in Wet/Damp Conditions.

Do Not Operate in an Explosive Atmosphere.
Keep Product Surfaces Clean and Dry.

Safety Terms and Symbols:
Terms in This Manual.

These terms may appear in this manual.

WARNING.

Warning statements identify conditions or practices that could result in injury or loss of life.

CAUTION.

Caution statements identify conditions or practices that could result in damage to this product or
other property.

Terms on the Product.

These terms may appear on the product.

DANGER

Indicates an injury hazard immediately accessible as you read the marking.

WARNING

indicates an injury hazard not immediately accessible as you read the marking.

CAUTION

Indicates a hazard to property including the product.

Symbols on the Product.

These symbols may appear on the product: Attention refer to operation Instructions.

This instrument has double insulation.

Getting Started:

The current probe enables a general purpose oscilloscope to display AC and DC current signals up
to 100 amps Peak (70A RMS). The current probe can also make AC and DC measurements with a
multimeter by using the recommended accessory MT-246N (BNC-to-banana) plug adapter.

Summary of Contents for PT-710

Page 1: ...m service procedures To Avoid Fire or Personal Injury Connect and Disconnect Properly Connect the probe output to the measurement instrument before connecting the probe to the circuit under test Disconnect the probe input and the probe ground from the circuit under test before disconnecting the probe from the measurement Instrument Observe All Terminal Ratings To avoid fire or shock hazard observe...

Page 2: ...tatements identify conditions or practices that could result in injury or loss of life CAUTION Caution statements identify conditions or practices that could result in damage to this product or other property Terms on the Product These terms may appear on the product DANGER Indicates an injury hazard immediately accessible as you read the marking WARNING indicates an injury hazard not immediately ...

Page 3: ...t needed for AC measurements unless your instrument cannot isolate a DC component if present OFF Range switch Slide the switch from OFF to either the 100 mV A or 10mV A range When either range is selected the probe is turned on and the green battery indicator lights If the indicator does not light see Battery Notes and Battery Installation Battery indicator The green battery indicator lights when ...

Page 4: ...pe voltage input channel to DC volts and the voltage sensitivity scale to 5m V div 2 Move the OFF Range switch to the 100mV A or 10mV A position to turn on the probe The PT 710 current probe has a green LED power battery indicator If the LED does not light replace the battery or use specified power adaptor 3 Use the ZERO adjustment to zero or offset the probe output detection of residual magnetic ...

Page 5: ...quency current the momentary peaks may be quite high 7 PT 710 a multifunctional current probe When connecting to a digital meter use the recommended MT 246N BNC to banana adapter Connect the black lead to the meter COM black letters on the meter and the red lead to the VΩ input red letters on the meter 8 To measure only AC current set the meter to measure AC volts 9 To measure DC current set the m...

Page 6: ...age V Rating Range 10mV A Range 100mV A Max Working voltage V Max floating voltage V DC 100 10 600 600 DC peak AC 100 10 600 600 AC peak 100 10 600 600 AC peak peak 200 20 1200 RMS CAT III 70 7 600 600 RMS CAT II 70 7 600 600 RMS CAT I 70 7 600 600 Voltage and current ratings 8 ...