background image

NEVER LEAVE HEATER UNATTENDED WHILE  

CONNECTED TO A POWER SOURCE

© 2021, Pinnacle Climate Technologies,Inc

Ceiling Mounted Electric Heater User’s Manual

11

LIMITED WARRANTY

Pinnacle Climate Technologies, Inc.

 warrants this heater 

to the original retail purchaser only, to be free from defects 

in material and workmanship for a period of one (1) year 

from the date of initial purchase. This product must be 

properly installed, maintained and operated in accordance 

with the instructions provided.

Pinnacle Climate Technologies, Inc. 

requires reasonable 

proof of your date of purchase from an authorized retailer 

or distributor.  Therefore, you should keep your sales slip, 

invoice or cancelled check from the original purchase.  

This Limited Warranty shall be limited to the repair or 

replacement of parts, which prove defective under normal 

use and service within the warranty period, and which 

Pinnacle Products International , Inc.

 shall determine at 

its reasonable discretion. 

This warranty does not apply to products purchased for 

rental use. 

This Limited Warranty does not cover any failures or 

operating difficulties due to normal wear and tear, accident, 

abuse, misuse, alteration, misapplication, improper 

installation or improper maintenance and service by you 

or any third part.  Failure to perform normal and routine 

maintenance on the heater, shipping damage, damage 

related to insects, birds or animals of any kind, and damage 

due to weather conditions are also not covered.   

In addition, the Limited Warranty does not cover damage 

to the finish, such as scratches, dents, discoloration, rust or 

other weather damage, after purchase. 

All transportation costs for the return of damaged product 

or parts will be the responsibility of the purchaser. Upon 

receipt of damaged item, 

Pinnacle Climate Technologies, 

Inc. 

will examine the item and determine if defective. 

Pinnacle Climate Technologies, Inc. 

will repair or replace 

and return the item, freight pre-paid. 

If 

Pinnacle Climate Technologies, Inc. 

finds the item to 

be in normal operating condition, or not defective the item 

will be returned freight collect. This Limited Warranty is 

in lieu of all other express warranties. 

Pinnacle Climate 

Technologies, Inc.

 disclaims al warranties for products 

that are purchased from sellers other than authorized 

dealers or distributors. 

AFTER THE PERIOD OF THE ONE (1) YEAR EXPRESS 

WARRANTY EXPIRES, 

Pinnacle Climate Technologies, 

Inc. 

DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, 

INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES 

OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR 

APPLICATION. FURTHER, 

Pinnacle Climate Technologies, 

Inc. 

SHALL HAVE NO LIABILITY WHATSOEVER TO PURCHASER 

OR ANY THIRD PARTY FRO ANY SPECIAL, INDIRECT, PUNITIVE 

INCIDENTAL, OR CONSEQUENTIAL DAMAGES. 

Pinnacle 

Climate Technologies, Inc. 

assumes no responsibility for 

any defects caused by third parties. This Limited Warranty 

gives the purchaser specific legal rights; a purchaser may 

have other rights depending upon where he or she lives. 

Some states do not allow the exclusion or limitation of 

special, incidental or consequential damages, or limitations 

on how long a warranty lasts, so the above exclusion and 

limitations may not apply to you.  

Pinnacle Climate Technologies, Inc. 

does not authorize 

any person or company to assume for it any other 

obligation or liability in connection with the sale, installation, 

use, removal, return or replacement of its equipment, and 

no such representations are binding on 

Pinnacle Climate 

Technologies, Inc.

Always be sure to specify the model number and serial 

number when making any claim with 

Pinnacle Climate 

Technologies, Inc. 

For your convenience, use the space 

provided below to list this information.

Model #:________________________________

Serial #:________________________________

Date of Purchase: ________________________

Locating Your Serial Number:

Your serial number can be found on the heater’s rating label. It will begin with the letters MEFH followed by 9 

digits. For Example: MEFH-00-00-00000. Have your Serial Number ready before calling customer service  

at 800-641-6996.

XXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXX

XXXXXXXXXXXXXXXXX

Serial Number Label

Summary of Contents for MASTER MH-425A-240

Page 1: ...ngs Do not route cord under furniture or appliances Arrange cord away form the traffic area where it will not cause a tripping hazard Do not operate any heater with a damaged cord or plug or after hea...

Page 2: ...E THE HEATER WITH THE ILLUMINATING RISK OF ELECTRIC SHOCK WARNING WARNING WARNING Extreme caution is necessary when any heater is used by or near children or invalids whenever the heater is left opera...

Page 3: ...e or chemical agents are present For safe and efficient operation and to extend the life of your heater keep your heater clean Reference the MAINTENANCE INSTRUCTIONS WARNING RISK OF ELECTRIC SHOCK OR...

Page 4: ...ft2 388 Power Volts 240V 60Hz Amps 15 6 Heat Settings 1 Specifications subject to change without notice FEATURES MH 425A 240 WHAT S IN THE BOX Figure 1 1 Front Guard 2 Fan 3 Thermostat 4 Error Indica...

Page 5: ...being blocked by furniture curtains or storage materials Hot air from the heater may damage certain fabrics and plastics To reduce the risk of fire do not store or use gasoline or other flammable vap...

Page 6: ...nut to secure bracket to handle in smaller holes 4 Locate wood stud in wall or joist in ceiling to mount heater NOTE Wall stud must be able to support 12 lbs continuously 5 Use holes in bracket to mar...

Page 7: ...NECTED TO A POWER SOURCE 2021 Pinnacle Climate Technologies Inc Ceiling Mounted Electric Heater User s Manual 7 ASSEMBLY INSTRUCTIONS Figure 3 Figure 4 Figure 5 Angled Mounting Level Mounting HANGING...

Page 8: ...ol is activated The heating element will be shut off until the unit has cooled to a safe level The fan will continue to operate Once the heater has reached a safe level 158 F 70 c the heater will turn...

Page 9: ...TED TO A POWER SOURCE 2021 Pinnacle Climate Technologies Inc Ceiling Mounted Electric Heater User s Manual 9 WIRING DIAGRAM Error Indicator Light Thermostat Adjustable Thermostat Power Indicator Light...

Page 10: ...will not glow red to produce heat 1 Heater is operating correctly Do not feel heat or air flow 1 No power to heater 2 Desired room temperature reached 3 Heater does not heat area in front of heater i...

Page 11: ...condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other express warranties Pinnacle Climate Technologies Inc disclaims al warranties for prod...

Page 12: ...Sauk Rapids MN 56379 USA Toll Free 800 641 6996 Fax 320 251 2922 Web www masterindustrialproducts com Email info pinnacleclimate com 2021 Pinnacle Climate Technologies Inc...

Page 13: ...ar quemaduras no deje que la piel desnuda toque las superficies calientes Al mover el calentador uti lice las asas si se incluyen Deje que el calentador se enfr e antes de tocarlo RIESGO DE DESCARGA E...

Page 14: ...calentando excesivamente Si se ilumina la alarma apague de inmediato el calentador y revise si hay objetos sobre o cerca del calentador que podr an haber bloqueado el flujo de aire o provocado las alt...

Page 15: ...galo limpio Consulte las INSTRUCCIONES DE MANTENIMIENTO ADVERTENCIA RIESGO DE DESCARGA EL CTRICA O INCENDIO Aseg rese de tener desconectada la energ a el ctrica en el panel el ctrico principal antes d...

Page 16: ...aje 15 6 Ajustes de calor 1 Las especificaciones pueden cambiar sin previo aviso CARACTER STICAS MH 425A 240 QU HAY EN LA CAJA Figura 1 1 Protecci n delantera 2 Ventilador 3 Perilla del termostato 4 L...

Page 17: ...e el calentador detr s de puertas debajo de toalleros o en una zona donde se pueda bloquear con muebles cortinas o materiales de almacenamiento El aire caliente del calentador puede da ar ciertas tela...

Page 18: ...os 4 Localice el montante de madera en la pared o la viga en el cielo raso para montar el calentador NOTA La viga del techo debe poder aguantar 12 lb 5 4 kg de manera continua 5 Use los orificios en e...

Page 19: ...NTE DE ALIMENTACI N Manual del usuario del calentador el ctrico montado en cielo raso 2021 Pinnacle Climate Technologies Inc 7 INSTRUCCIONES DE ARMADO Figura 3 Figura 4 Figura 5 Figura 2 Montaje en ng...

Page 20: ...precauci n Esta luz se encender cuando se active el control de seguridad contra el sobrecalentamiento El elemento t rmico se apagar hasta que la unidad se enfr e a un nivel que sea seguro El ventilado...

Page 21: ...ALIMENTACI N Manual del usuario del calentador el ctrico montado en cielo raso 2021 Pinnacle Climate Technologies Inc 9 DIAGRAMA EL TRICO LUZ INDICADORA DE ERROR TERMOSTATO TERMOSTATO AJUSTABLE LUZ IN...

Page 22: ...e adelante dispersar el calor por toda la habitaci n para calentar toda el rea 1 Compruebe las conexiones el ctricas conecte el calentador a la fuente de alimentaci n 2 El termostato se apagar una vez...

Page 23: ...efectuoso se devolver el art culo con el flete por cobrar Esta Garant a Limitada reemplaza a todas las dem s garant as expresas Pinnacle Climate Technologies Inc se desiste de todas las garant as de p...

Page 24: ...Sauk Rapids MN 56379 EE UU Llamada sin costo 800 641 6996 Fax 320 251 2922 Web www masterindustrialproducts com Correo electr nico info pinnacleclimate com 2021 Pinnacle Climate Technologies Inc...

Reviews: