background image

NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR 

WHILE CONNECTED TO A POWER SOURCE

© 2013, Pinnacle Products International, Inc. 

Kerosene Forced Air Heater User’s Manual 

®

2

Safety Information

The products described in this manual are 

kerosene direct-fired, forced air heaters. 

Kerosene forced air heaters are primarily 

intended for use for temporary heating of 

buildings under construction, alteration or repair. 

Direct-fired means that all of the combustion 

products of the heater enter the heated space. 

This appliance is rated at 98% combustion 

efficiency, but does produce small amounts of 

carbon monoxide.

Carbon monoxide is toxic. Humans can tolerate 

only small amounts of carbon monoxide and so 

precautions should be taken to provide proper 

ventilation. Failure to provide proper ventilation 

in accordance with the instructions in this manual 

can result in death.
People with breathing problems should consult a 

physician before using this heater. 
Early signs of carbon monoxide poisoning 

resemble the flu. Symptoms of improper 

ventilation / carbon monoxide poisoning are:

Headache 

• Dizziness •

 Nausea 

• 

Dry Mouth 

Sore Throat 

 Burning of Nose and Eyes

If you experience any of these symptoms: 

GET FRESH AIR AT ONCE! 

Have your heater 

serviced and check for proper ventilation. Some 

people are more affected by carbon monoxide 

than others. These include: pregnant women, 

those with heart or lung problems, anemia or those 

under the influence of alcohol or at high altitudes. 

Use this heater in only well ventilated areas! 

Provide at least a three square foot 

 

(2,800 sq cm) opening of outside air for 

every 100,000 Btu / Hr heater rating. Refer to 

“Ventilation” on page 7 for further instructions. 

ALWAYS use only the electrical power (voltage and 

frequency) specified on the model plate of the heater.

ALWAYS use only three-prong, grounded outlet and 

extension cord. 
ALWAYS use only 14 AWG or better extension cord.
ALWAYS unplug the heater when not in use.  
ALWAYS install the heater so that it is not directly 

exposed to water spray, rain, dripping water, or wind.

NEVER use fuels such as gasoline, benzine, paint 

thinners or other oil compounds in this heater.
NEVER refill the heater’s fuel tank while the 

heater is operating or still hot. This heater is 

EXTREMELY HOT while in operation. 
NEVER block air inlet (rear) or air outlet (front).
NEVER use duct work in front or rear of heater.
NEVER move or handle heater while still hot.
NEVER transport heater with fuel in tank.
NEVER use with an external fuel tank.

Keep all combustible materials away from this heater. 

Minimum Clearance From Combustibles

45-KFA

70T-KFA 125T-KFA 175T-KFA 215T-KFA

Top

4 ft.

4 ft.

4 ft.

4 ft.

4 ft.

Sides

4 ft.

4 ft.

4 ft.

4 ft.

4 ft.

Front

8 ft.

8 ft.

8 ft.

8 ft.

10 ft.

ALWAYS locate heater on a stable and level surface. 
If your heater is equipped with a thermostat, 

once it is plugged in, it can start at anytime in 

accordance with the thermostat setting. 

RISK OF INDOOR AIR 

POLLUTION!

WARNING

CARBON MONOXIDE POISONING 

MAY LEAD TO DEATH!

DANGER

RISK OF BURNS, FIRE AND 

EXPLOSION!

WARNING

RISK OF ELECTRIC SHOCK!

WARNING

CAUTION! HOT WHILE IN 

OPERATION. DO NOT TOUCH. 

KEEP CHILDREN, ANIMALS, CLOTHING AND 

COMBUSTIBLES AWAY FROM HEATER. 

WARNING

Summary of Contents for HeatStream HS- 45-KFA

Page 1: ...ersons who can follow and understand these instructions should operate or service this heater If you need heater info such as an operating manual labels etcetera contact Pinnacle Products Internationa...

Page 2: ...to comply with the precautions and instructions provided with this heater can result in death serious bodily injury property loss or damage from the hazards of fire soot production explosions burns as...

Page 3: ...ell ventilated areas Provide at least a three square foot 2 800 sq cm opening of outside air for every 100 000 Btu Hr heater rating Refer to Ventilation on page 7 for further instructions ALWAYS use o...

Page 4: ...2 7 2 8 Phase Single Single Single Single Single Specifications subject to change without notice Hot Air Outlet Upper Shell Lower Shell Fuel Tank Fan Guard Pressure Gauge Fuel Gauge Fuel Cap Side Cove...

Page 5: ...les in the upper housing with the 2 holes in the handle as shown in Figure 3 2 Insert screws 13 mm and tighten firmly Cord Wrap Assembly 1 Insert tabs into square slots in shell support and line up sc...

Page 6: ...8 mm open end wrench 19 mm open end wrench Assembly Instructions Models HS 125T KFA HS 175T KFA HS 215T KFA What s In The Box 50 mm Screws 4 30 mm Screws 8 8 mm Nuts 12 Tires 2 Cord Wraps 2 Axle Nuts...

Page 7: ...l 4 screws are secure 7 Attach rear handle with 2 long screws 50 mm and 2 nuts through the third hole from the rear of the heater on either side See Figure 6 8 Tilt the heater up gently so it is resti...

Page 8: ...HIS HEATER NOTE Kerosene should only be stored in a blue container that is clearly marked Kerosene Never store kerosene in a red container Red is associated with gasoline Ventilation Risk of indoor ai...

Page 9: ...ob to desired temperature setting The thermostat set range is from 40 F to 110 F 3 Move power switch to On position The power indicator light and room temperature display will illuminate and heater wi...

Page 10: ...WITH THE UNIT HAVE A COMPETENT SERVICEMAN MAKE ANY NECESSARY ADJUSTMENT OR REPAIRS Use only original equipment parts The use of alternate or third party components can cause unsafe operating conditio...

Page 11: ...osene Contaminated fuel could make cleaning the fuel filter necessary immediately NOTE To remove the filter from models 45 70T KFA turn filter 90 clockwise To remove the filter from models 125T 175T 2...

Page 12: ...r Pump Pressure HS 45 KFA 3 0 PSI HS 70T KFA 4 0 PSI HS 125T KFA 5 0 PSI HS 175T KFA 7 5 PSI HS 215T KFA 9 0 PSI Tolerance 10 NOZZLES Nozzles should be cleaned or replaced at least once per heating se...

Page 13: ...rcuit board 8 Ignitor wire not connected to spark plug 9 Defective ignitor 1 Fill tank with fresh kerosene 2 Adjust pump pressure 3 Clean replace spark plug 4 Clean replace fuel filter 5 Clean replace...

Page 14: ...International Inc Kerosene Forced Air Heater User s Manual 13 17 14 16 11 15 12 40 43 47 34 4 19 17 3 5 35 8 7 1 2 9 28 29 27 32 21 22 23 31 26 30 29 18 56 48 50 51 39 38 6 46 45 44 36 42 10 41 20 33...

Page 15: ...0100 70 054 0100 26 Lint Filter 70 054 0102 70 054 0102 70 054 0102 70 054 0102 70 054 0102 27 Output Filter 70 054 0100 70 054 0100 70 054 0100 70 054 0100 70 054 0100 28 Intake Filter 70 054 0101 7...

Page 16: ...be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other express warranties Pinnacle Products International Inc disclai...

Reviews: