Pinnacle International HH-125-OFR-A User'S Manual And Operating Instructions Download Page 2

Table of Contents

Warnings.................................................................. 2
Safety Information ................................................ 2-3
Specifications .......................................................... 3
Features .................................................................. 4
Theory of Operation ................................................ 5
Assembly

................................................ 5

Fuels........................................................................ 5
Ventilation................................................................ 5
Operation................................................................. 6
Maintenance......................................................... 6-7
Storage .................................................................... 7
Exploded Parts Drawing.......................................... 8
Replacement Part Listing ....................................... 9
Wiring Diagrams.................................................... 10
Troubleshooting ..................................................... 11
Warranty .................................................. Back Page

Safety Information

This is a kerosene, direct-fired, radiant heater.  It is 
primarily intended for use for temporary heating of 
buildings under construction, alteration or repair.  
Direct-fired means that all of the combustion products of
the heater enter the heated space.  This appliance is rated
at 98% combustion efficiency, but does produce small
amounts of carbon monoxide.  Carbon monoxide is toxic.
Humans can tolerate small amounts of carbon monoxide,
and precautions should be taken to provide proper 
ventilation.  People with breathing problems should consult
a physician before using the heater.  Failure to provide
proper ventilation in according to this manual can result in
death.  Early signs of carbon monoxide poisoning 
resemble the flu.  Symptoms of improper ventilation are:

* headache * dizziness * burning of the nose and eyes 

* nausea  *  dry mouth  *  sore throat  *

If the heater is being used in the presence of others, be
sure to inform them of all proper safety precautions, 
operating procedures and hazards.  

Some people are

more affected by carbon monoxide than others.

These

are pregnant women, people with heart or lung disease or
anemia, those under the influence of alcohol or at high 
altitudes.  For optimal performance of this heater, it is
strongly suggested that 1-K kero sene be used. 1-K
kerosene has been refined to virtually eliminate 
contami nants, such as sulfur, which can cause a rotten egg
odor during the operation of the heater. However, #1 or #2
fuel oil (diesel fuel) may also be used if 1-K kero sene is not
available. Be advised that these fuels do not burn as clean
as 1-K kerosene, and care should be taken to provide more
fresh air ventilation to accommodate any added contami-
nants that may be added to the heated space. Use of #1 or
#2 fuel oil may result in more periodic maintenance.
- Check the heater thoroughly for damage before each

use. DO NOT operate a damaged heater.

- DO NOT modify this heater or operate a heater that has

been modified from it’s original state.

Suitable for outdoor use.

Use this heater only in well

ventilated areas!  Provide at least 3 square feet (2,800 sq
cm) of opening per 100,000 Btu of rated operation (See
page 5).

- Never use heater in occupied dwellings.

- Never use this heater in living or sleeping areas.

Fire, burn, inhalation, and explosion
hazard. Keep combustibles, such as

building materials, paper or cardboard, a safe distance
away from the heater as recommended by these 
instructions. Never use the heater in spaces which contain
products such as gasoline, solvents, paint thinners, dust
particles, volatile or airborne combustibles, or any
unknown chemicals.

California Residents:

Combustion by-products pro-

duced when using this product contain carbon monoxide,
a chemical known to the state of California to cause 
cancer and birth defects (or other reproductive harm).

Do not operate this heater until you
have read, and thoroughly understand

these safety and operating instructions. Failure to comply
with the precautions and instructions provided with this
heater can result in death, serious bodily injury, property
loss or damage from the hazards of fire, soot production,
explosion, burns, asphyxiation or carbon monoxide poi-
soning. Only persons who can read and understand these
instructions should use or service this heater.
Not for use in homes or recreational vehicles.

This is an unvented portable heater. It
uses air (oxygen) from the area in which

it is used. Adequate combustion and ventilation air must
be provided. Refer to VENTILATION Page 5.

Massachusetts Residents:

Massachusetts state

law prohibits the use of this heater in any building which is
used in whole or in part for human habitation. Use of this
heating device in Massachusetts requires local fire 
department permit (M.G.L.C. 148, Section 10A).

Page 2

Pinnacle Products International, Inc.  Oil-Fired Radiant Heater User’s Manual

WARNING

WARNING

WARNING

Carbon Monoxide poisoning may lead to
death!

NEVER LEAVE HEATER 

UNATTENDED WHILE BURN-

ING OR WHILE CONNECTED

TO A POWER SOURCE

Oil-Fired Radiant

Heaters

Risk of indoor air pollution!

WARNING

DANGER

New York City Residents:

The New York City Fire

Code prohibits the storage, handling and use of kerosene
fueled heaters for space heating.  Any person violating
that provision may be punished by a fine up to $10,000
and a term of imprisonment up to 6 months.

Minimum clearance from Combustibles:

Top 

   

       Sides          Front

125k 

6 ft.            6 ft.             6 ft.

Summary of Contents for HH-125-OFR-A

Page 1: ...oper use of this heater can cause serious injury Keep this manual for future reference GENERAL HAZARD WARNING Be sure to comply with the instructions and warnings provided with this heater or death se...

Page 2: ...fied from it s original state Suitable for outdoor use Use this heater only in well ventilated areas Provide at least 3 square feet 2 800 sq cm of opening per 100 000 Btu of rated operation See page 5...

Page 3: ...er while still hot Never transport heater with fuel in its tank NEVER refill the heater s fuel tank while heater is operating or still hot This heater is EXTREMELY HOT while in operation Bulk fuel sto...

Page 4: ...fan blows air up and around the chamber during operation and also runs during the cool down period Electrical System Protection The heater s electrical system is protected by a circuit breaker that pr...

Page 5: ...t may be added to the heated space Using diesel fuel can cause excess soot production DO NOT use any fuel that is not approved above Kerosene should only be stored in a blue container that is clearly...

Page 6: ...r are protected by a fuse mounted in the PC board If the heater fails to fire check this fuse first and replace if necessary Also check the power source to be sure that the proper voltage is being pro...

Page 7: ...clean the lens of the Photocell Figures 8 and 9 Long Term Storage Unscrew the Drain Bolt and drain fuel Using a small amount of kerosene rinse and swirl the kerosene inside of the Fuel Tank Empty the...

Page 8: ...ED WHILE BURN ING OR WHILE CONNECTED TO A POWER SOURCE Oil Fired Radiant Heaters Replacement Parts Item Description HH 125 OFR A 1 Fuel Tank Assembly 72 001 0110 2 Fuel Gauge Assembly 72 022 0110 3 Fu...

Page 9: ...ower Motor Assembly 72 045 0100 25 Photocell Assembly 72 038 0200 26 Spark Plug 75 075 0200 27 Burner Body 72 035 0210 28 Nozzle 72 036 0100 29 Burner Blade 72 035 0500 30 Diffusion Cap 72 036 0200 31...

Page 10: ...model HH 125 OFR A subject to change without notice Page 10 Pinnacle Products International Inc Oil Fired Radiant Heater User s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURN ING OR WHILE CONNECTED...

Page 11: ...nections See Wiring Diagrams Page 10 7 Re attach Transformer wires to Spark Plug 8 Replace Transformer Fan does not operate when heater is plugged in and Power Switch is in the ON position 1 Broken el...

Reviews: