Programming the SAT-6
9
Auto test
enter the time of the day in HH:MM format, for sending test reports
enter an interval for the test reports in HH:MM format (in
addition to the time of the day)
Report codes
The default “FF” codes can be used with the following formats: ContactID, PAF, and NPAF. All
other formats require specific other than “FF” codes.
The codes are hexadecimal: 0 - 15 and A-F (press
repeatedly to enter a character).
The default codes are listed in the following table:
Code
Event
Z1, Z2... Z6
Alarm in zones 1-6.
RS1, RS2... RS6
Restore codes for zones 1-6.
Zone Fail
Zone fail
AC/RESTR
AC fault/Restore
LB/RESTR
Low battery/Restore
PF/RESTR
Low PCB voltage (less than 9V)/Restore.
Check the battery!
PH/RESTR
Telephone fault/Restore
TST
Test report
PNC
Panic code
FUS/RESTR
Zone voltage fault/Restore
ONG/OFG
Arm/disarm using a code other than a user code
ON1-8/OFF1-8
Arm/disarm using user codes 1-8
BPS/RST
Zone bypassed/Restore
Auto test hour
0 :0
ENTR
Auto test time
0 hr. 0 min
ENTR
Technician code
Report codes <R>
ENTER/NEXT/END
Report codes <R>
RS1:FF RS2:FF
Report codes <R>
Zone Fail: FF
Report codes <R>
AC:FF RESTR:FF
Report codes <R>
LB:FF RESTR:FF
Report codes <R>
LB:FF RESTR:FF
Report codes <R>
PF:FF RESTR:FF
Report codes <R>
PH:FF RESTR:FF
Report codes <R>
TST:FF PNC:FF
Report codes <R>
FUS:FF RESTR:FF
Report codes <R>
ONG:FF OFG:FF
Report codes <R>
ON1:FF OF1:FF
Report codes <R>
BPS:FF RSR:FF
Report codes <R>
ENTER/NEXT/END
Select:
CPTN XX en 6.10
Report codes <P>
ENTER/NEXT/END
ENTR
Report codes <R>
Z 1:FF Z 2:FF
ENTR
ENTR
ENTR
ENTR
ENTR
ENTR
ENTR
ENTR
ENTR
ENTR
ENTR
ENTR
ENTR
ENTR