PZE X4VP4
Operating Manual PZE X4VP4
1003205-EN-08
12
Relay outputs
777586
787586
Max. short circuit current IK
1 kA
1 kA
Utilisation category
In accordance with the standard
EN 60947-4-1
EN 60947-4-1
Utilisation category of safety con-
tacts delayed
AC1 at
240 V
240 V
Min. current
0,01 A
0,01 A
Max. current
5 A
5 A
Max. power
1200 VA
1200 VA
DC1 at
24 V
24 V
Min. current
0,01 A
0,01 A
Max. current
5 A
5 A
Max. power
120 W
120 W
Utilisation category
In accordance with the standard
EN 60947-5-1
EN 60947-5-1
Utilisation category of safety con-
tacts delayed
AC15 at
230 V
230 V
Max. current
5 A
5 A
DC13 (6 cycles/min) at
24 V
24 V
Max. current
4 A
4 A
Utilisation category in accordance
with UL
Voltage
240 V AC G.U. (same polarity)
240 V AC G.U. (same polarity)
With current
5 A
5 A
Voltage
24 V DC Resistive
24 V DC Resistive
With current
5 A
5 A
Pilot Duty
B300, R300
B300, R300
External contact fuse protection,
safety contacts
In accordance with the standard
EN 60947-5-1
EN 60947-5-1
External contact fuse protection,
delayed safety contacts
Max. melting integral
100 A²s
100 A²s
Blow-out fuse, quick
6 A
6 A
Blow-out fuse, slow
4 A
4 A
Blow-out fuse, gG
6 A
6 A
Circuit breaker 24 V AC/DC,
characteristic B/C
4 A
4 A
Conventional thermal current
5 A
5 A
Contact material
0,2 µm Au
0,2 µm Au
Times
777586
787586
Switch-on delay
With automatic start after power
on typ.
230 ms
230 ms
With automatic start after power
on max.
400 ms
400 ms