PSSu E AI SHT2

Operating Manual 1003113-EN-02

}

Decentralised system PSSuniversal I/O

Summary of Contents for PSSu E AI SHT1

Page 1: ...PSSu E AI SHT2 Operating Manual 1003113 EN 02 Decentralised system PSSuniversal I O...

Page 2: ...umentation will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Interne...

Page 3: ...Section 4 Function Description 11 4 1 Block diagram 11 4 2 Module features 11 4 2 1 Functions 11 Section 5 Installation 13 5 1 General installation guidelines 13 5 1 1 Dimensions 13 5 2 Installing the...

Page 4: ...ure reference 1 1 2 Terminology System environment A and B The PSSu system can be used in two different system environments The module s applic ation area is described in the chapter Intended Use of t...

Page 5: ...uation that could lead to serious injury and death and indicates preventive measures that can be taken CAUTION This refers to a hazard that can lead to a less serious or minor injury plus material dam...

Page 6: ...determine the module s function Details of the base modules that can be used are available in the chapter entitled Intended Use 2 2 Module features The product has the following features 1 analogue cu...

Page 7: ...B Base module 1 Labelling strip with Name of electronic module Order number Serial number Hardware version number 2D code 2 Labelling strip for the terminal configuration on the base module 3 Name of...

Page 8: ...tighten the screw terminal on base modules with screw termin als With mechanism to operate the cage clamp on base modules with cage clamp ter minals 9 Round connection holes connection levels 1 2 3 a...

Page 9: ...n the PSSuniversal Installation Manual The module is designed for use in an industrial environment It is not suitable for use in a domestic environment as this can lead to interference The following i...

Page 10: ...y accident preven tion Have read and understood the information provided in this description under Safety And have a good knowledge of the generic and specialist standards applicable to the specific a...

Page 11: ...nection O0 and IO1 connection O1 are eval uated by analogue current inputs Scaling is applied during evaluation via an analogue input module with an input resistance of 115 Ohm e g PSSu E F AI I Scali...

Page 12: ...nction Description Operating Manual PSSu E AI SHT2 1003113 EN 02 12 Example Input current II0 200 mA Output current IO0 at R1 R2 20 mA Output current IO1 at R2 10 mA I0 O0 O1 0V O0 O1 IO1 IO0 II0 R1 R...

Page 13: ...atic discharge Electrostatic discharge can damage components Ensure against discharge before touching the product e g by touching an earthed conductive sur face or by wearing an earthed armband 5 1 1...

Page 14: ...ead module Please note For mechanical reasons it is not possible to mix base modules with screw terminals and base modules with cage clamp terminals All contacts should be protected from contamination...

Page 15: ...s with outputs may only be inserted and removed when the load is switched off Unforeseeable error reactions may be triggered if modules are inserted and removed under load When an electronic module is...

Page 16: ...ual PSSu E AI SHT2 1003113 EN 02 16 5 3 1 Inserting an electronic module Procedure The electronic module must audibly lock into position 1 Mark the electronic module using the labelling strips 2 Schem...

Page 17: ...ng operation The configuration data is re tained when a module is changed Effects System environment A In the event of a potential FS communication error the FS section of the PSSu sys tem and all rel...

Page 18: ...ct the mounting rail to the functional earth via an earthing terminal In environments with strong EMC interference base modules without a C rail provide better protection if the shield is connected Us...

Page 19: ...seated 21 11 1 3 2 4 5 6 Please note The minimum cable cross section for field connection terminals on the base modules is 0 14 mm2 AWG26 The maximum cable cross section for field connection terminals...

Page 20: ...can use crimp pliers crimp form A or C conforming to EN 60947 1 such as the PZ 1 5 or PZ 6 5 from Weidm ller for example Maximum torque setting 0 8 Nm Use copper wiring 6 2 Terminal configuration Bas...

Page 21: ...onnection 13 23 linked within the base module 14 Input I0 24 0 V analogue 21 11 22 12 23 13 24 14 Screw terminals PSSu BP 1 12 S PSSu BP 1 12 S T Cage clamp terminals PSSu BP 1 12 C PSSu BP 1 12 C T W...

Page 22: ...minals PSSu BP C 1 12 C PSSu BP C 1 12 C T With C rail 11 Output O0 21 Output O1 12 Output O0 22 Output O1 13 23 C rail supply shield connection 13 23 16 26 linked within the base module 14 Input I0 2...

Page 23: ...ng the module Input circuit Current range 0 0 2 A single pole referenced to earth 21 11 22 12 24 14 23 13 PSSu E AI SHT1 O0 O0 O1 O1 I0 0V 0V I0 21 11 22 12 23 13 24 14 PSSu E F AI I 0V I0 n c n c 0V...

Page 24: ...Scaling Analogue output O0 1 10 Analogue output O1 1 20 Internal resistance Connection O0 O0 10 150 Ohm Connection O1 O1 6 750 Ohm Deviations from the measuring range limit value Output variable error...

Page 25: ...leration 10g Duration 16 ms Max operating height above sea level 2000 m Airgap creepage In accordance with the standard EN 60664 1 EN 61131 2 Overvoltage category II Pollution degree 2 Protection type...

Page 26: ...PSSu BP 1 8 C Base module without C rail with cage clamp terminals 312 601 PSSu BP C 1 8 S Base module with C rail and screw terminals 312 610 PSSu BP C 1 8 C Base module with C rail and cage clamp t...

Page 27: ...p ThE SPIrIT Of SAfETY are registered and protected trademarks of Pilz Gmbh Co KG in some countries We would point out that product features may vary from the details stated in this document dependin...