OPERATING MANUAL
PSEN op4F/H-A series
NOTE: The OSSDs are pulsed. The following diagram shows the time
characteristic of the OSSDs.
115 µs
500 ms
1000 ms
OSSD in safe state
OSSD2
OSSD1
24 V DC
GND
24 V DC
GND
Fig. 26 – Time characteristic of the OSSDs