The safety switch shall not be used as mechanical 
end stop! 

Position of mechanical stop adjustable
(not supplied with safety switch) 

 

Actuating forces (Extraction force): 

 
Standard = 10 N 

 

PSEN me3.02 = 30 N 

 

PSEN me2.1, PSEN me3.01, PSEN me3.11, 
PSEN me3.21 = 100 N 

 

Mounting M20/M16 cable gland/cable:

 

Connection type: 
2 or 4 screw connectors M3,5 or 
6 screw connectors M3 
Conductor cross section: 
single core 0,5-1,5 mm²/litz wire with 
connector sleeve 0,5-1,5 mm² 

After mounting the gland 
remove the piece inside 

 

4 different directions of actuation by turning the cap 
in position A or B: 

1. remove 

the 

actuator 

2. open 

cover 

lid 

3.  snap of cap 
4. remove 

cap 

5. turn 

cap 

6. latch 

cap 

7.  for fixing the cap close cover lid 
 
 

Cover for 
unused entry 

 

 

Electrical connection

 

 

The electrical connection shall only be carried out by trained and qualified personnel!  

 
The electrical contacts of the switches 

PSEN me2

 and 

PSEN me2.1

 feature 2 screw terminals M3,5. 

Tightening torque M = 0,8 Nm. 
The electrical contacts of the switches 

PSEN me3, PSEN me3.01, PSEN me3.02, PSEN me3.1 

and 

PSEN me3.11

 

feature 4 screw terminals M3,5. 
Tightening torque M = 0,8 Nm. 
The electrical contacts of the switches 

PSEN me3.2

 and 

PSEN me3.21

 feature 6 screw terminals M3. 

Tightening torque M = 0,6 Nm. 
 
The connection requires a stranded wire with ferrule or a solid wire with a cross section of 0,5 – 1,5 mm². 
For safety circuits acc. EN 60204 use the normally closed contact(s) (N.C.) only. 

Summary of Contents for PSEN me2

Page 1: ...ate actuator are suitable for the mounting on safety guards They are designated to trigger switching operations in control circuits Function If the safety guard is opened the contact s with forced disconnection will break the safety control circuit safety contacts get opened Safety instructions Improper installation or manipulation of the safety switch renders the personal protection function usel...

Page 2: ...rs 40 mm with M5 screws acc DIN 912 Installation Installation by trained and qualified personnel only To mount the switch gear 2 screws M5 shall be used Actuator PSEN me2AS and PSEN me2AR The user shall make sure that the actuator is form fit mounted The actuator mounting should not be solvable with simple tools The mounting requires 2 screws M5 acc DIN 912 The switch and the actuator shall be ali...

Page 3: ...r mounting the gland remove the piece inside 4 different directions of actuation by turning the cap in position A or B 1 remove the actuator 2 open cover lid 3 snap of cap 4 remove cap 5 turn cap 6 latch cap 7 for fixing the cap close cover lid Cover for unused entry Electrical connection The electrical connection shall only be carried out by trained and qualified personnel The electrical contacts...

Page 4: ...7 5 1 Degree of protection II protective insulation Mechanical data Enclosure Thermoplastic glass fiber reinforced UL94 V0 Cover Thermoplastic glass fiber reinforced UL94 V0 Ambient air temperature 30 C to 80 C 22 F to 176 F Cable entry PSEN me2 PSEN me2 1 3 x M16x1 5 PSEN me3 PSEN me3 01 PSEN me3 02 3 x M20x1 5 PSEN me3 1 PSEN me3 11 3 x M20x1 5 PSEN me3 2 PSEN me3 21 2 x M20x1 5 Protection class...

Page 5: ...The drive shall only be energized when the safety guard is in its closed position Maintenance Inspection The switching device is maintenance free For trouble free operation and a long service life the device should be inspected regularly Ensure that all components are secure and tight switching functions operate properly all sealing gaskets are in proper condition the components show no signs of t...

Page 6: ...5 07 2005 Page 12 of 12 Document 0800000423 Version 2 2518 05 Pilz GmbH Co KG Sichere Automation Felix Wankel Straße 2 D 73760 Ostfildern Deutschland Phone 49 711 3409 0 Fax 49 711 3409 133 E Mail techsupport pilz de www pilz com Template 0850174292 Orig 2 ...

Reviews: