PSEN 4.2a/b/p/M12
Operating Manual PSEN 4.2a/b/p/M12
22188-EN-02
23
PSEN cs4.2 M12 and PSEN cs4.2p
General
541209
541210
Approvals
CE, GOST, TÜV, cULus Listed
CE, GOST, TÜV, cULus Listed
Sensor's mode of operation
Transponder
Transponder
Electrical data
541209
541210
Supply voltage
Voltage
24 V
24 V
Type
DC
DC
Voltage tolerance
-20 %/+20 %
-20 %/+20 %
Output of external power supply
(DC)
1,0 W
1,0 W
Max. switching frequency
3 Hz
3 Hz
Switching current per output
100 mA
100 mA
Breaking capacity per output
2,4 W
2,4 W
Max. cable capacitance at the safe-
ty outputs
No-load, PNOZ with relay con-
tacts
400 nF
400 nF
PNOZmulti, PNOZelog, PSS
400 nF
400 nF
Max. inrush current impulse
Current pulse, A1
0,58 A
0,58 A
Pulse duration, A1
1,0000 ms
1,0000 ms
Max. overall cable resistance Rl-
max
Single-channel at UB DC
1000 Ohm
1000 Ohm
Inputs
541209
541210
Number
2
2
Voltage at inputs
24 V DC
24 V DC
Input current range
5,0 mA
5,0 mA
Potential isolation between input
and voltage for the internal module
bus
No
No
Semiconductor outputs
541209
541210
OSSD safety outputs
2
2
Signal outputs
1
1
Potential isolation from system volt-
age
No
No
Short circuit-proof
Yes
Yes
Times
541209
541210
Test pulse duration, safety outputs
450 µs
450 µs
Switch-on delay
After UB is applied
1,0 s
1,0 s
Inputs typ.
13 ms
13 ms
Inputs max.
20 ms
20 ms
Actuator typ.
45 ms
45 ms
Actuator max.
120 ms
120 ms