background image

PSEN 2.1p-24

Operating Manual PSEN 2.1p-24
21100-EN-13

| 4

Introduction

Validity of documentation

This documentation is valid for the product PSEN 2.1p-24, ATEX. It is valid until new docu-
mentation is published.
This operating manual explains the function and operation, describes the installation and
provides guidelines on how to connect the product.

Using the documentation

This document is intended for instruction. Only install and commission the product if you
have read and understood this document. The document should be retained for future ref-
erence.

Definition of symbols

Information that is particularly important is identified as follows:

DANGER!

This warning must be heeded! It warns of a hazardous situation that poses
an immediate threat of serious injury and death and indicates preventive
measures that can be taken.

WARNING!

This warning must be heeded! It warns of a hazardous situation that could
lead to serious injury and death and indicates preventive measures that can
be taken.

CAUTION!

This refers to a hazard that can lead to a less serious or minor injury plus
material damage, and also provides information on preventive measures
that can be taken.

NOTICE

This describes a situation in which the product or devices could be dam-
aged and also provides information on preventive measures that can be
taken. It also highlights areas within the text that are of particular import-
ance.

Summary of Contents for PSEN 2.1p-24

Page 1: ...PSEN 2 1p 24 Operating Manual 21100 EN 13 PSEN sensor technology...

Page 2: ...nta tion will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Internet...

Page 3: ...6 Disposal 6 For your safety 7 Unit features 7 Function description 8 Block diagram 8 Operating distances 8 Lateral and vertical offset 9 Wiring 9 Pin assignment 10 Requirements and connection to eva...

Page 4: ...articularly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive...

Page 5: ...cordance with EN 60947 5 3 PDDB only in connection with the operator PSEN 2 1 20 and the suitable evaluation devices see Requirements and connection to evaluation devices 10 The following is deemed im...

Page 6: ...evices systems and machines the person has to be informed of the state of the art and the applicable national European and international laws directives and standards It is the company s responsibilit...

Page 7: ...bout to connect the unit This will prevent potential contamination The connector should be protected from accidental loosening e g using a cable tie WARNING Ignition spark from cable separator connect...

Page 8: ...with the following components Actuator PSEN 2 1 20 see Order reference 19 and a connected evaluation device see Requirements and connection to evaluation devices 10 Block diagram Actuator Safety swit...

Page 9: ...ngth lmax Rlmax Ri Rl km Imax Rlmax Max overall cable resistance see evaluation device s technical details Ri Internal resistance sensor see Technical details 17 Rl km Cable resistance km of the cable...

Page 10: ...own in an unoperated condition Assignment of the 4 pin connector 1 2 3 4 white brown blue black Requirements and connection to evaluation devices For use of PSEN 2 1p 24 ATEX in accordance with DIN EN...

Page 11: ...valuation device must fulfil the requirements in the Technical details 17 of PSEN 2 1p 24 ATEX Always comply with the max switching current safety contacts of PSEN 2 1p 24 ATEX Outputs at the evaluati...

Page 12: ...uation devices Non Ex area Ex area I0 I1 PNOZmulti PSENmag 3 1 2 4 T1 T0 3 1 2 4 11 12 13 14 PSEN i1 brown white blue black Legend I0 Input OSSD I1 Input OSSD T1 T2 Test pulse outputs Non Ex area Ex a...

Page 13: ...ts made of non magnetic material e g brass or stainless steel Avoid the risk of damages from foreseeable external influences by attaching the safety switch and actuator If necessary safety switch and...

Page 14: ...eference Safety switches and actuators should only be secured using M4 screws with a flat head e g M4 cheese head or pan head screws Use screws made of non magnetic material e g brass Adjustment The s...

Page 15: ...atmosphere Carry out a monthly function test on the safety switch and actuator Always test the function with the PSEN i1 interface and connected evaluation device The safety function may only be chec...

Page 16: ...PSEN 2 1p 24 Operating Manual PSEN 2 1p 24 21100 EN 13 16 Dimensions in mm 13 6 5 13 8 5 36 22 6 8 4 5 26 10 6 M8x1 8 5 4 5 36 22 26 19 19...

Page 17: ...nt safety contacts 10 mA Max breaking capacity safety contacts 0 3 W Max permitted total power dissipation 170 mW Times Reaction time actuator removed 2 ms Environmental data ATEX certification SEV 12...

Page 18: ...0947 5 2 Yes follow installation guidelines Connection type M8 4 pin male connector Material Top PC Max torque setting Safety switch 1 Nm Actuator 1 1 Nm Dimensions Height 45 mm Width 26 mm Depth 13 m...

Page 19: ...ade cable straightplug2m Female connector M8 straight 4 pin 2 m 533 111 PSEN Kabel Winkel cable angleplug 5m Female connector M8 angled 4 pin 5 m 533 120 PSEN Kabel Gerade cable straightplug 5m Female...

Page 20: ...00 Series connection Product type Features Order no PSEN i1 Interface for 4 PSEN 2 Interface PSEN i1 for connecting and evaluating several safety switches PSEN ma 535 110 PDP67 F 8DI ION Decentralised...

Page 21: ...fetyNET p THE SPIRIT OF SAFETY are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this document d...

Reviews: