Overview
2.1
Scope of supply
2.2
Unit features
Using the product PNOZ mmc3p:
Expansion module for connection to a base unit from the configurable control system
PNOZmulti Mini
The product has the following features:
}
Can be configured in the PNOZmulti Configurator
}
Connection for PROFIBUSDP
}
Station addresses from 0 ... 99, selected via rotary switch
}
Status indicators for communication with PROFIBUSDP and for errors
}
24 virtual inputs and outputs on the control system PNOZmulti can be defined in the
PNOZmulti Configurator for communication with the fieldbus PROFIBUSDP . The num
ber of inputs and outputs can be extended to 128. Please note that when the extended
inputs and outputs 24 127 are used they have different properties (see document en
titled "Communication Interfaces").
}
Max. 1 PNOZ mmc3p can be connected to the base unit
}
Plugin connection terminals:
either springloaded terminal or screw terminal available as an accessory (see order
reference)
}
For details of the PNOZmulti Mini base units that can be connected, please refer to the
document "PNOZmulti System Expansion".