Surface mount housing

[1]

[2]

[3]

Legend:

}

[1]: Actuator

}

[2]: Plastic nut

}

[3]: Contact block with flat connector

Installation

CAUTION!

The pushbutton should always be installed with the supply voltage switched
off.

Panel mount version

NOTICE

Use a mounting plate with a smooth surface to ensure a tight seal.

}

Prepare another opening in the mounting plate (see diagram).

}

Guide the thread of the E-STOP pushbutton into the mounting plate opening and se-
cure it using the plastic nut (size 24 spanner). Note the max. torque setting of 1.5 Nm.

Summary of Contents for PIT es6 Series

Page 1: ...PIT es6 PIT esb6 Operating instructions 22138 EN 06 Control and signal devices...

Page 2: ...umentation will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Interne...

Page 3: ...inition of symbols 4 Safety 5 Intended use 5 Safety regulations 5 Safety assessment 5 Use of qualified personnel 5 Warranty and liability 6 Disposal 6 For your safety 6 Unit features 6 Installation 7...

Page 4: ...at is particularly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates prev...

Page 5: ...t technical or electrical modification to the product Use of the product outside the areas described in this manual Use of the product outside the technical details see chapter entitled Technical deta...

Page 6: ...ed to not having followed the guidelines in the manual Operating personnel are not suitably qualified Any type of modification has been made e g exchanging components on the PCB boards soldering work...

Page 7: ...pushbutton should always be installed with the supply voltage switched off Panel mount version NOTICE Use a mounting plate with a smooth surface to ensure a tight seal Prepare another opening in the...

Page 8: ...ring PIT esb6 16 PIT esb6 10 PIT esb6 13 21 14 13 22 22 12 21 11 The contact is closed when the actuator is snapped in place Attach the contact block to the actuator neck NOTICE Always twist to insert...

Page 9: ...s PIT es6 PIT esb6 22138 EN 06 9 Operation NOTICE Check the function of the emergency stop device before commissioning for the first time and then at regular intervals at least annually Dimensions PIT...

Page 10: ...ntact current 1 mA E STOP Utilisation category In accordance with the standard EN 60947 5 1 Contacts AC15 at 250 V Current 1 5 A Contacts DC13 at 24 V Current 2 A Conventional thermal current 6 A Cont...

Page 11: ...hieve the required safety level for your plant machine Safety characteristic data B10d in accordance with EN ISO 13849 1 2015 and EN 62061 127 500 Lambdad Lambda in accordance with EN 62061 0 20 Order...