PIT en1.0/PIT en1.1
Operating Manual PIT en1.0/PIT en1.1
1002172-EN-09
| 8
Connection to evaluation device
Connection to PNOZ X, PNOZsigma, PNOZelog
PNOZ e1p
PNOZ e1.1p
PNOZ e1vp
PNOZ e6.1p
PNOZ e6vp
PNOZ s3
PNOZ s4
PNOZ s5
PNOZ X2C
PNOZ X2
PNOZ X2.7P
PNOZ X2.8P
PNOZ X2.9P
white
brown
green
yellow
PNOZ e5.11p
white
brown
green
yellow
PNOZ X3.1
PNOZ X3P
PNOZ X3
PNOZ X3.10P
PNOZ XV2
PNOZ XV2P
PNOZ XV3
PNOZ XV3P
white
brown
green
yellow
Connection to PDP67 F 8DI ION
The connection is made via the adapter PSEN mag ad (see operating manual PSEN adapt
PSS67/PDP67 4p).
Connection to PNOZmulti
Safety gate with switch type 3
I0, I1: Inputs
T0, T1: Test pulse outputs
white
brown
green
yellow
Connection to PSS with or without SafetyBUS p
Safety gate with switch type 3
I0, I1: Inputs
O16, O17: Test pulse outputs
white
brown
green
yellow
We recommend that you use the standard function block SB064 or SB066 for connecting to
a PSS.