PSWZ X1P
Operating Manual PSWZ X1P
21005-EN-11
| 8
Unit features
}
Measuring inputs for 3- or 1-phase motors
}
Measuring voltage on both channels can be set jointly
}
1 Reset input
}
Positive-guided relay outputs:
– 2 safety contacts (N/O), instantaneous
– 1 auxiliary contact (N/C), instantaneous
}
2 semiconductor outputs
}
LED display for:
– Standstill on channel 1/2
– Supply voltage/fault
}
Semiconductor outputs signal:
– Supply voltage/fault
– Switch status
}
Feedback loop for monitoring external contactors
}
Plug-in connection terminals (either spring-loaded terminal or screw terminal)
}
See order reference for unit types
Safety features
}
The relay meets the following safety requirements:
– The circuit is redundant with built-in self-monitoring.
– The safety device remains effective in the case of a component failure.
– The correct opening and closing of the safety device relays is tested automatically in
each on-off cycle.
}
The unit monitors the measuring circuits for open circuit. If an open circuit occurs
between the unit and the motor or on the motor itself, the unit immediately switches off.
}
The standstill monitor prevents the plant from being enabled in the following cases:
– Power supply failure
– Component failure
– Measuring circuits are open circuit
– Coil defect/open circuit