Unit features
}
Outputs using semiconductor technology:
–
2 safety outputs
–
1 auxiliary output
–
2 test pulse outputs
}
Connection options:
–
E-STOP pushbuttons
–
Safety gate limit switches
–
Start button
–
Proximity switch
}
To process signals from output signal switching devices (OSSDs) on light grids
}
LED display for:
–
Supply voltage
–
Switch status of the safety contacts
}
2 logic inputs (AND/OR) for logic connections between several units
}
Feedback loops for monitoring external contactors
}
Detection of shorts across contacts via test pulse outputs
Safety features
The relay meets the following safety requirements:
}
The circuit is redundant with built-in self-monitoring.
}
The safety device remains effective in the case of a component failure.
}
The safety outputs are tested periodically using an off-test.
Block diagram/terminal configuration
Input
Input
&
Feed-
back
Diag-
nostic
Power
Test
Pulse
Output
S12
S35
S36
Y6
Y5
S11 S21
14
24
Y32
A1
A2
S22
Start
S34
Y4