PNOZ c2
Operating Manual PNOZ c2
22212-EN-04
7
Unit features
}
Positive-guided relay outputs:
– 2 safety contacts (N/O), instantaneous
}
1 semiconductor output (auxiliary output)
}
Connection options for:
– Type 2 or Type 4 light guards
– safe sensors with semiconductor outputs (OSSD)
– Start button
}
LED display for:
– Supply voltage
– Switch status channel 1
– Switch status channel 2
Safety features
The safety relay meets the following safety requirements:
}
The circuit is redundant with built-in self-monitoring.
}
The safety function remains effective in the case of a component failure.
}
The correct opening and closing of the safety function relays is tested automatically in
each on-off cycle.
Block diagram/terminal configuration
14
S33
S35
S34
13
23
24
Y32
PNOZ c2
S22
S12
A2
A2
A2
A1
A1
A1
Power
Ch. 1
Ch. 2
t
D
12ms
* Insulation from non-marked area: Safe separation (overvoltage category III),
Insulation between relay contacts: basic insulation (overvoltage category III), safe separa-
tion (overvoltage category II)