PSEN opII mirror column
Operating Manual PSEN opII mirror column
1004629-EN-02
10
[1]
[3]
[4]
[5]
[6]
[7]
[2]
[5]
Legend
[1] Cover plate
[2] Retainer for mirror column
[3] Base plate for attachment to floor
[4] Slot hole for attaching the adjustable base unit to the floor
[5] Markings to align the mirror in the protected field
[6] Spring element
[7] Adjusting nut
Scope of supply of adjustable base unit
}
1 adjustable base unit
}
3 locking screws to attach the deviating mirror to the adjustable base unit
Installation
Important information
PSEN opII mirror column has a dead zone on the side of the base unit (see diagram).
Calculating the dead zone:
Distance from the safety light curtain to the floor - (protected field height of safety light cur-
tain - effective protected field height of safety light curtain)/2
Make sure that the safety curtain's protected field is completely covered by the deviating
mirror.