PSEN cs6.2 M12/8
Operating Manual PSEN cs6.2 M12/8
1003425-EN-06
14
Vertical offset when aligning to the triangle or square marking
Alignment 1/2: Actuator aligned to the triangle or square marking on the
switch
[4]
[5]
[8]
[9]
[1]
[3]
[2]
8 4 0
-12
-8
-4
0
12
8
4
8
4
0
-12
-8
-4
0
12
8
4
12 16
8
4
0
12 16
16
-16
[4]
12
16
8 4 0
12
16
-16
16
[6]
[5]
[7]
Legend
[1] Hysteresis
[2] Typical operating distance S
O
[3] Typical release distance S
r
[4] Offset in mm
[5] Operating distance in mm
[6] Response range
[7] Status of LED
[8] Square marking
[9] Triangle marking