40
Installation example:
The full face of the safety switch is installed on the subplate.
As a result, the edges of the safety switch base are protected from shock.
CAUTION!
Change of the release distance S
ar
with non-flush installation
If you install the safety switch non-flush within electrically or magnetically
conductive material, the value for the assured release distance
S
ar
can also
change.
Procedure:
Fig.: Sensing faces on the sensor
1. Drill holes (for M5 screws) in the mounting surface to secure the actuator and sensor
(see
Dimensions in mm [
43]
).
2. Use a screw to fix the sensor to the mounting surface.
Make sure that the sensor marking that is be used for operation can be operated using
the actuator from the right side.
3. Do not fully tighten the second screw on the safety switch.
PSEN cs2.13p ATEX
Operating Manual PSEN cs2.13p ATEX
21133-2EN-1