40
Chapter 6 Data collection
6.1 Summary
PBAT-GATE gateway provide 4 channel RS485 communication, collect battery data at
setting time, equipped with
Control linkage alarm, inner resistance testin
g
6.2 Collector function
Collector module including single cell unit collector and battery group collector. Each
battery group should equip with same quantity single cell unit collector and 1 group
collector
(
1
)
. Single cell unit collector will charge each battery cell voltage, temperature and inner
resistance
(
2
)
. Group collector will charge battery group’s group voltage, serial current, group
temperature
(
3
)
Each gateway equip with 4 channel RS485 port
(
4
)
Each RS485 channel connect maxim 60 pieces single cell collector
(
5
)
Each gateway support maxim 4 group battery connection
(
6
)
Node on one RS485 channel must be attributed to the same battery group
(
7
)
Each group single cell unit should be separate ID number (ID number same as slave
address)