The maximum configuration of the Pillar Axiom 600 system is:
● One Pilot
● Four Slammers
● 64 Bricks
defines the maximum configuration limits for a Pillar Axiom 600 system.
The maximum number of Bricks that a Pillar Axiom 600 system can support
depends on the number of Slammers in the system. The maximum
configurations are given in terms of width (the number of strings), depth (the
number of Bricks for each string), and the maximum number of Bricks that the
system supports.
Table 7 Configuration limits for a Pillar Axiom 600 system
Number of
Slammers
Maximum
number of
strings
Maximum
number of Bricks
in a string
Maximum
number of Bricks
in the system
1
4
8
32
2
8
8
64
3
8
8
64
4
16
8
64
Brick storage enclosures can contain Fibre Channel (FC), Serial ATA (SATA), or
solid state drives (SSDs), depending upon the type of RAID controllers.
further classifies the configuration limits by the type of Bricks in the Pillar
Axiom 600 system. The maximum number of a specific Brick (SATA, FC, or
SSD) allowed in the Pillar Axiom 600 system also depends on the number of
Slammers in the system.