Support equipment
Table 3 Support equipment
Name
Identifications/References
Qty
Reference
Remark
Safety clip (circuit breaker hold
open)
Part T12-030
AR
Supplies
Table 4 Supplies
Name
Identifications/References
Qty
Reference
Remark
Cable tie
Part P09-008
AR
Sealant
Part P08-018
AR
Adhesive
Part P08-102
AR
Spares
Table 5 Spares
Name
Identifications/References
Qty
Reference
Remark
None
Safety Conditions
CAUTION
DO NOT TOUCH THE RED FLASHING BEACON FILAMENTS WITH THE BARE HANDS, FINGERPRINTS
AND SKIN OIL WILL DAMAGE THE FILAMENTS.
Note
To identify the consumables used in this procedure refer to the list of consumable items AMM
12-B-20-31-00-00A-
070A-A
.
Note
To identify the Aerospace Ground Equipment (AGE) and tools used in this procedure, refer to the List of AGE and
Tools, TEM
12-B-00-00-00-00A-060A-A
.
Procedure
1
General
This procedure is applicable to the top and bottom red flashing beacons.
2
Removal of the Top and Bottom Red Flashing Beacons
2.1
Open and install a Safety clip (circuit breaker hold open) (Pt.No. T12-030) on these circuit breakers:
−
RED BEACON (GENERATOR 1 BUS)
−
EXT LTS GND OP (ESSENTIAL BUS)
−
NAV LIGHTS (MAIN BUS).
PC-12/47E AMM Doc No 02300, ISSUE 01 REVISION 26 MSN 545, 1001-1719,
1721-1999
12-B-AM-00-00-00-I
UNCLASSIFIED
Effectivity: All
12-B-33-46-00-00A-920A-A
UNCLASSIFIED
2021-12-04 Page 2