Support equipment
Table 3 Support equipment
Name
Identifications/References
Qty
Reference
Remark
Safety clip (circuit breaker hold
open)
Part T12-030
AR
Supplies
Table 4 Supplies
Name
Identifications/References
Qty
Reference
Remark
Lockwire
Part P02-007
AR
Glyptal
Part P08-076
AR
Spares
Table 5 Spares
Name
Identifications/References
Qty
Reference
Remark
None
Safety Conditions
Note
To identify the consumable items used in this procedure refer to the Consumable Materials List, AMM
12-B-20-31-
00-00A-070A-A
.
Note
To identify the AGE and tools used in this procedure, refer to the List of AGE and Tools, TEM
12-B-00-00-00-00A-
060A-A
.
Procedure
1
Removal
1.1
Open and install a Safety clip (circuit breaker hold open) (Pt.No. T12-030) on these circuit breakers:
−
A/P SERVO (AVIONIC 1 BUS)
−
A/P SERVO ENABLE (AVIONIC 1 BUS).
1.2
Remove the center carpet:
−
For Executive interior, refer to AMM 12-B-25-21-04-00A-920A-A
−
For Standard interior, refer to AMM 12-B-25-22-04-00A-920A-A.
1.3
Open the access panel 12EZ.
1.4
Disconnect the electrical connector Figure 1 [4] from the roll actuator Figure 1 [5].
1.5
Cut and remove the lockwire from the bolts Figure 1 [1].
1.6
Hold the roll actuator Figure 1 [5]. Remove the two bolts Figure 1 [1] and washers Figure 1 [2] then
remove the roll actuator from the mount Figure 1 [3].
PC-12/47E AMM Doc No 02300, ISSUE 01 REVISION 26 MSN 545, 1001-1719,
1721-1999
12-B-AM-00-00-00-I
UNCLASSIFIED
Effectivity: All
12-B-22-10-03-00A-920A-A
UNCLASSIFIED
2021-12-04 Page 2