Section II - Air Compactors
1 Setup Instructions
1) Remove PIG
®
Waste Compactor from pallet and place on floor.
2) If desired, permanently mount the compactor to the floor using the pre-drilled holes in the
base. Up to 1/2" floor anchors can be used. Floor anchoring not required for operation
(anchors not included).
3) Remove the yellow plug in the top of the air pump with wrench. Replace with the attached
black vent cap. Do not over tighten the vent cap with wrench.
4) Remove the pipe plug from the air intake pipe located on the back of the unit, attached to
the side of the Rear Pivot (Part # 19 on exploded view).
5) Screw a male air connect chuck into the 3/8" pipe.
6) Attach air chuck and air line (both not included) to male air connect.
7) Ground unit to earth ground with provided grounding wire.
Note: A ground is provided with DRM654 & DRM655.
Note: An in line air filter (included) and oiler (not included) should be used with this unit.