© 2018 Pierce Manufacturing Inc. All Rights Reserved.
Controls, Indicators, and Features / 4-13
GENERAL
Controls, Indicators, and Features
4-4.
Heating, Ventilation, Air Conditioning (HVAC)
Figure 4-5: HVAC Control Panel
1100
4-4.1
Defroster
This is a heat-only, recirculation-only, in-dash unit. Air intake is through the dash panel upper grill openings. The air
outlet is through a fixed louvered panel directly below the inlet grill. Controls consist of temperature and fan speed.
IMPORTANT: As the defrost and heat are recirculation-only systems, the A/C may be required to dry the
air in situations where the windshield might fog over.
4-4.2
Heater
There are two heater units, one under each rear-facing seat. Each unit has an outlet at the floor, blowing rearward,
and an inlet immediately above in the seat riser. In addition, each unit has a duct routed to the first officer and driver
foot area. These outlets are located in the seat riser next to the engine tunnel. Controls consist of temperature and
fan speed. The left and right units are controlled simultaneously.
4-4.3
Air Conditioning
The air conditioning system has a roof mounted condenser and a ceiling mounted evaporator unit. The evaporator
is mounted in the center of the cab. There are six fully adjustable circular louvers for the driver and first officer and
six louvers for the rear seating positions. The temperature and fan speed are controlled with electronic keypad style
switches. One switch controls both front and rear.
Summary of Contents for Enforcer
Page 1: ... 2018 Pierce Manufacturing Inc Part No PM C OM014 SEN 0718 Operator s Manual Saber Enforcer ...
Page 2: ......
Page 18: ...FOREWORD 1 6 To the Owner and Operator 2018 Pierce Manufacturing Inc All Rights Reserved ...
Page 30: ...SAFETY 2 12 Safety and Responsibility 2018 Pierce Manufacturing Inc All Rights Reserved ...
Page 122: ...OPERATION 5 60 Driving the Vehicle 2018 Pierce Manufacturing Inc All Rights Reserved ...
Page 184: ...A 4 2018 Pierce Manufacturing Inc All Rights Reserved ...