Note: The Concorde must have a rev 3 vCP card in the system to handle
768Kb conferences. To determine if the current card will work at 768Kb,
reboot the system and watch the start-up tests. If the vCP is shown in all
caps (VCP) then it is an older card and must be replaced. A good card will be
shown with a lower case v (vCP).
!"
Support for G.722 audio coding in the following bit rates: 336 Kbps, 384 Kbps, 672 Kbps,
and 768 Kbps.
!"
The Configuration, Remote diagnostics, Telnet, FTP and Upload utilities are now
protected by utilizing the same (configurable) user name and password.
!"
Dialing profiles for the 210 TA have been changed: a list of predefined bandwidth profiles
is preset for setting the bandwidth of incoming and outgoing calls, as shown below (see
Chapter 6 of the VIU-323 User Guide for further information). The use of a dialing prefix
to indicate the required bandwidth profile eases the operation of the 210 TA in that
mode. (For the configurable port default bandwidth, a prefix is not needed.)
To Force Calling
Bandwidth to:
Use Prefix:
2 x 64 Kbps (2B)
#00
128 Kbps
#10
256 Kbps
#20
384 Kbps
#30
768 Kbps
#70
2 x 56 Kbps (2B) (restricted)
#01
112 Kbps (restricted)
#11
224 Kbps (restricted)
#21
336 Kbps (restricted)
#31
672 Kbps (restricted)
#71
To Force Receiving
Bandwidth to:
Use Suffix:
2 x 64 Kbps (2B)
00
2 x 56 Kbps (2B)
01
128 Kbps
10
112 Kbps
11
224 Kbps
21
256 Kbps
20
336 Kbps
31
384 Kbps
30
672 Kbps
71
768 Kbps
70
!"
Remote configuration via PPP can now be used from Windows 95/98/NT.
!"
RADVision OnLAN Tools is now installed automatically using the RADVision OnLAN Video
Tools CD-ROM.
!"
Improved User Guide.
4 Fixed
Bugs
!"
There was a problem working with third-party gatekeepers in Direct Mode. This has been
fixed.
5 Known
Issues
!"
T.120 does not work with the Concorde or Venue. It must be disabled or there will be
video problems.