6.3  Default (recycling) 

The following shall be done on Picomeds EFP 2005 when it shall be used by a new user. If 
necessary, make a copy of this page, fill inn serial number, version and tick off the points 
which are done with signature and date at each point, and file it as your routines requires. 
Serial number: 

 

 

 

Check the equipment. Is there any physical damages, cracks etc in box or foil? 
Check that foil is not damaged, that it is fastened all around the edges and that it not has 
loosened from its surface. If it is marked with former users name, remove this marking. If not 
possible to remove name, replace foil (can be ordered from supplier). 
Clean the device. 
Ensure that all components are available, amplifier box and outdoor unit. 
Make a function check. 
The equipment has to be connected to an indoor unit. It is recommended to do this before the 
equipment is disconnected. 
Ensure that all functions are working properly: check if “ding-dong” is responding, and that it 
is possible to have 2-way communication between out- and in indoor units. 
Adjust potentiometer for outdoor loudspeaker volume (“GAIN”) clockwise until end-stop, 
thereafter counter clockwise 90º. 
Store. 

6.4  Technical data 

 
Type 

Picomed EFP 2005 doorphone. 

Operating 

Pushbutton on outdoor unit. 
The conversation is activated from indoor unit (not included). 
Voice direction is electronically controlled.  

Power supply 

From indoor unit, 12 VDC. 

Current consumption 

< 250 mA. 

Temperature 

Amplifier box: 0˚C to +40

 C. 

Outdoor unit: -20˚C to +40

 C. 

Measurements 

Amplifier box: LxWxH: 117 x 94 x 14 mm. 
Outdoor unit: LxWxH: 130 x 100 x 45 mm. 

Weight 

Amplifier box: 160 g. 
Outdoor unit: 250 g. 

Programmable parameters 

Outdoor volume can be adjusted by technician. It is recommended 
that the preset value is kept unaltered. 

 

 

Waste management 

Dispose as electronic waste. 

Developed and manufactured in  Norway. 
 

6.5  CE markings 

Picomeds environmental control systems are developed and manufactured in accordance with 
EU directives, national regulations and harmonised standards which are applicable, and 
thereafter marked with the CE-mark. The Declaration of Conformity is in English version and 
it is set out on the next page.

Summary of Contents for EFP 2005

Page 1: ...hanged revisionlist to new type 01 08 08 Bent Håvard Sollid New version of outdoor unit Ch 6 2 1 changed text Ch 6 2 3 6 2 4 changed wiring diagram 01 01 12 Bent Håvard Sollid Added wiring diagram for the new version of PicoCombi MK II Contents Documentation EFP 2005 1 Introduction 2 2 Getting started installation 2 3 User manual 2 3 1 Accessories 3 4 Maintenance 3 4 1 Cleaning 3 4 2 Outdoor use 3...

Page 2: ...icolo and PicoCombi or an Erifox PABX Indoor unit is not included in the EFP 2005 shipment EFP 2005 made for Picolo PicoCombi can not be connected to an Erifox version or v v The Erifox version is clearly marked with Erifox Find a suitable place to mount the outdoor unit It is recommended to place it where it is shielded for wind and precipitation There is space for the users name on the outdoor u...

Page 3: ...in and snow The reason for this is that water will be able to get inside the box and degrade the equipments function 5 Troubleshooting If your equipment does not behave as expected first of all try to solve the problem yourself using the following table Symptom Possible cause Recommended action Completely dead Light indicator not illuminated No power connected to the indoor unit the EFP 2005 is po...

Page 4: ...PCB A red LED illuminates when power is connected Potentiometer GAIN Can be used to regulate speaker volume in outdoor unit Outdoor unit Front part with microphone loudspeaker and pushbutton Frontfoil glued on front part Picomeds logo product name and space made for the users name on it with a label waterproof pen etc Backside has 6 electrical connections Frame for wall mounting 6 1 Fixed mounting...

Page 5: ... connection points are connected to each other or to components on the PCB Description of the connections 12V and GND is powersupply to the amplifier Only use direct current DC La Lb is sound between indoor unit and amplifier box DB is DoorBell one pole switch in outdoor unit Connects GND back to indoor unit LS is LoudSpeaker sound to loudspeaker in outdoor unit Non polarized Mic and Mic is sound ...

Page 6: ...EFP 2005 loudspeaking doorphone Page 6 6 2 3 Wiring diagram for Picolo PicoCombi version I ...

Page 7: ...EFP 2005 loudspeaking doorphone Page 7 6 2 4 Wiring diagram for Picolo PicoCombi version II OBS this is for PicoCombi MK II not same diagram as for MKI ...

Page 8: ...EFP 2005 loudspeaking doorphone Page 8 6 2 5 Wiring diagram for Erifox PABX ...

Page 9: ... and that it is possible to have 2 way communication between out and in indoor units Adjust potentiometer for outdoor loudspeaker volume GAIN clockwise until end stop thereafter counter clockwise 90º Store 6 4 Technical data Type Picomed EFP 2005 doorphone Operating Pushbutton on outdoor unit The conversation is activated from indoor unit not included Voice direction is electronically controlled P...

Page 10: ......

Reviews: