Absolute maximum Ratings
Supply voltage range: 12 .. 26 V
Max. output current U-monitor, NTC: 1 mA
Input voltage range Disable_Poti: 0 .. 5 V
Input voltage range trigger input, disable: 0 .. 15 V
Security Advice:
Do not touch any leads of the output or the output capacitors as they are connected to a
high voltage of up to 80 V.
Mechanical Details of the Baseplate
All dimensions in millimetres.